Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Trendsetter 400/800 III |
||
Machines affected |
Serial number TG0421 and higher |
||
Component |
Registration pins (blocks) |
||
Symptoms |
Plot fails with this error message. |
||
Cause |
Some Trendsetter workstations were incorrectly configured with Controlled Release (CR) 2.3. CR 3.0 is required to support the universal drum on Trendsetters with serial number TG0421 and higher. |
||
Solution |
Upgrade to CR 3.0. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
30 Jan 2008 |
||