Solutions
|
- Make sure that the TECs are on the actuator.
- Check the polarity of the clamp reed magnets.
- Take a magnet to each TEC and make sure that it is attracted by one of the circular
sensing magnets in the body of the TEC and repelled by the other. If both magnets are the
same, remove one of them, flip it over, clean its mounting pocket, and reattach using
GOOP.
- Check the TEC reed switches and replace as necessary.
- The switches should be more or less centered in their adjustment slots. With the clamps
on the backbone and the backbone up, individually isolate each reed switch using a
multimeter, and move the clamp by hand over its full range of motion on the trailing edge
clamp pins. The sensor should remain on at all times. If not, replace the sensor.
|