MPE firmware geometric correction (gc) NVS parameters |
|
Error |
One of the following errors occurs: |
|
Cause |
Cause 1: The set gc mss, set
gc mssa, and/or set mode <mode> mssa shift
parameters are incorrect.The workstation is specifying a large mainscan shift (around the drum). When error #16008 occurs, this shift is negative. When error #16010 occurs, this shift is too large and positive. Cause 2: In Trendsetter Base MPE Controlled Release 1.4 and 2.0, the main MPE firmware contains a bug that may cause edge detect to start with an invalid imaging mode before the imaging mode parameter has been received from the workstation. This results in errors 16008 or 16010. |
|
Solution |
Compare the values of the above gc parameters to the factory
settings, and adjust if necessary, as described in the firmware error message
descriptions:
16008 |
16010If these parameters are correct and the error message still occurs, apply |
|
Technical contact(s) |
Jeff Edgar | |
Submitted by |
Andrew So | |
Date submitted |
28 Jun 2006 |
|