Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order #D123

Applies to: Trendsetter Autoloader Priority =  Next PM
Reason = Cost
Release date = Aug 1999

Machines affected

Up to and including SA138

Component

Warning Light Driver assembly
Problem ECO C546 released the new Warning Light Driver assembly with a retrofit Kit # 05-0071 for all machines in the field. (#11 on the 100 Label) Then ECO C699 released a new (50-1522A) Interface Brd Assembly with a new Corner Light Driver Relay attached.
Solution(s) The retrofit Kit # 05-0071 contains a bracket and relay to protect the TEE board from a warning light bulb failure.
Parts needed Kit # 05-0071:
10-3987B cable assy
57-4881A mounting bracket
10-4037A cable, LMP relay - TEE (J24), TS4 AL
52-3057 washers (qty 2)
52-3252 screws, M3x8 (qty 2)

36-3156 warning lamp, 24V (qty 2)

Procedure
  1. Remove the existing interface bracket.
  2. Move the interface board, pushbutton assembly and cable assembly from the old bracket to the new.
  3. If the cable with relay (10-4037A) is not installed, use the 2 M3*8 screws and flat washers, and install the Relay from the front of the Interface Bracket. See  Operator Interface Assy 50-1522A for more details.
Action required
Prerequisite FCOs
Technical contact phorak@creo.com
Date submitted Aug 99
Modified by
Date modified

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.