Note: This FCO replaces FCO #04962.
|
|
|||
Applies to |
|
Priority:
|
|
|
|
|||
Component |
Unload table stepper motor cable (10-4855) |
||
|
|
|||
Problem |
The pins in the IDC connector at
the motor side of cable 10-4855A-A make poor contact, causing the cable
connector to heat up and melt. This results in erratic and noisy movement
from the unload cups, and can also cause damage to the stepper motor.
This problem has been noticed mostly on high-usage machines such as the Trendsetter News MCE devices. |
||
|
|
|||
Solution |
Replace unload table stepper motor cable with the latest version: 10-4855B-A. In this version, the contact pins in the IDC connector have been changed from low force to high force pins.
Note: There should be very few, if any, cables with part numbers 10-4855A-B or 10-4855A-C in existence, but if you find one, note that it already has the same improved connector as 10-4855B-A, and does not need to be replaced. |
||
|
|
|||
Parts needed |
New unload table motor cable: 10-4855B-A | ||
|
|
|||
Procedure |
|
||
|
|
|||
Technical contact |
|||
Date submitted |
25 Nov 2004 |
||