Product |
|
- Trendsetter Autoloader - MCE
- Trendsetter NEWS - MCE
|
|
Machines affected |
|
- Trendsetter Autoloader with MCE firmware version 1.18.10
- Trendsetter NEWS with MCE Main Master firmware version 1.22.06 and Slave version 1.10.01
|
|
Symptoms |
|
When load calibrate is used, a plate is picked but the picker does not go down and the device hangs. |
|
Cause |
|
The load calibrate command does not work in the firmware releases noted above. load calibrate is supposed to have the device set the mh DistSensorToLEC parameter during an automatic load. |
|
Solution |
|
A manual load calibrate must be done to set the mh DistSensorToLEC parameter:
- Carefully measure a plate in the mainscan direction.
- Load the measured plate manually, using the command
load m <mainscan mm> s <subscan mm> manual. For example:
load m 570 s 378 mi 2 ms 2 manual
- Unload the plate manually using
unload manual.
- Load the plate again using the command
load calibrate.
The mainscan plate size from the previous load is used as a calibration standard to update the mh DistSensorToLEC parameter.
|
|
Technical contact(s) |
|
Doug Jeffery |
Submitted by |
|
Doug Jeffery |
Date submitted |
|
28 Jul 2004 |