Cause 1: Threshold level set too low.
Solution:
Check the vacuum levels and thresholds:
PICKER UP
PICKER IN
PICKER VAC ON with no plate.
PICKER. Make a note of the vac level.
Pick the smallest plate and make a note of the vac level. The
value for SET AL PVT should be half-way between the readings for no
plate and a small plate. If it isn't, set it to the half-way value.
Cause 2: The picker does not move close enough to the
plates to get all of the suction cups on the plate (i.e., the bottom
of the picker head does not press the vacuum cups against the
plates).
Solution:
- Open the Operator door. Use an Omron key (Creo Part number
59-3450) to override the safety switch on the lower Operator
door, or turn the laser safety key in the power box to
mechanical hazards. Enter >>SET AL PCS 0
- Enter >>PICKER IN to pick a plate (use 32x44" or
the largest customer size).
- When the picker head moves in, push the picker toward the
plate.
- Enter >>PICKER, and check to see if the picker vacuum
reaches the threshold value (250 units).
- If so, check that the air regulator for the picker head is
set to 30psi. (The air regulator is directly in front of the
Autoloader manifold.) The bottom cups should now contact the
plate and the vacuum level should exceed 200 units.
- If the bottom of the picker head still does not contact the
plate, contact an Output Device Systems Engineer: a minor
adjustment of the Load Table may be required.
Cause 3: Load table support brackets are not installed on
the Autoloader.
Solution:
Install the load table support brackets on the Autoloader. See ECO
C443.
Cause 4: Broken valves in the suction cups
Solution:
Check for broken valves in suction cups.
Cause 5: Small plates that do not cover as many of the
suction cups.
Solution:
Decrease the vacuum threshold slightly to no less than 180
units.
Cause 6: A plate does not completely cover the vacuum cup
on one edge (for a picker with valved vacuum cups). This can cause
the valve to partially open, and result in a vacuum leak and a
threshold error.
Solution:
Shift the plates slightly to one side to prevent contact with
the offending cup.
Cause 7: Leaks or obstructions in the vacuum circuit
tubing.
Solution:
Check the vacuum circuit tubing for leaks and obstructions.
Replace the cable harness if it is too tight and presses the picker
tubing. |