Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
MCE TS AL & CL equipped with rotating unload table. |
||
Component |
unload table with rotator |
||
Symptoms |
Plates do not fully rotate on the unload table. Plates are skewed and a plate jam can occur at the entry to the processor. |
||
Cause |
MCE firmware does not have a long enough pause after rotating. |
||
Solution |
Problem has been fixed in MCE firmware version 1.28 and up. Install MCE Controlled Release 4.0 or higher. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
14 Apr 2005 |
||