Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
| Applies to |
|
|---|
| Component |
|
|---|
| Problem | A vacuum below threshold error (#15177) reported. |
|---|
| Cause | If the wrist cylinders are moving too slowly (see Delayed Wrist Action entry), the firmware will time out before the cups have grabbed the plate. |
|---|
| Solution | Increase the default value for SET ALDLY VAC from 20 seconds to 30 seconds. If necessary, increase this value to 45 to 60. There is no harm to throughput, it will simply take longer to post an error. |
|---|
| Technical contact | smontague@creo.com |
|---|
| Date submitted | August 24, 1999 |
|---|
| Date modified |
|---|