Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Components | Fixes and features | Installation and time | Known problems | Limitations | Dependencies | Workflow compatibility
NOTE: You must install the version of Service Shell in this controlled release before downloading firmware in this controlled release. See Installation instructions for details.
CD: 21-0140E (link points to CD files on Production's master server). Order the CD from CD.Requests@Creo.com.
Insert the relative file path to the appropriate files on the Production CD.
| Component | Version | Release notes |
|---|---|---|
| Print Console | 2.4.0.4 | Print Console 2.4.0 Quick Start Guide |
| Service Shell | 2.5 SP2 | Service Shell 2.5 SP2 Release Notes |
| MPE firmware | 1.56 | TSAL MPE 1.56 Release Notes |
| Firmware upgrade script | 4.34 | |
| Thermal Head 1/1.7 firmware | 1.95 | Release Notes |
| Version config file | TS 400-800-MPE-AL.ini |
SAP part number for Bill of Materials (including controlled release CD and Print Console Operator Manual): 20-0193B
For general information about controlled releases, see the FAQ for Controlled Releases.
Workflow items are not part of the release, but have been tested for compatibility.
None at time of release
Plot On command updatedPlot Headtest command modifiedConfig command modifiedMask save command addedDrum tick command addedList media stats command addedReset partial command removedFload bank 0 command removed from main firmware(It still exists in boot f/w)mode sssa or mode mssa are not zeroswidth and soffset locationsInstall in the order given. Total time - 4.25 hours
(minimum).
Review the Dependencies before beginning. Also
for more information, see the release notes for
each component.
| Task | Time |
|---|---|
| Check patches folder and apply as documented in the patch readme files. | 0.25 hour |
Install Service Shell - needed for checking
head/mpe f/w versions and for downloading the new f/w.
|
0.25 hour |
| Upgrade firmware | 1.0 hour |
| Upgrade Print Console | 0.25 hour |
| Check that device and all applications are functional including load/unload of small/medium/large size media | 2.0 hours |
| Demo and provide instructions on changes to customers | 0.5 hour |