03054     WSCOMM: Workstation issued flush while job was still active. Aborting job.
06027     DRUM: Plate not loaded correctly on drum, obstruction detected below LEC actuator
07020     CARRIAGE: Carriage control board error: cable not detected or undervoltage
07021     CARRIAGE: Carriage control board error: over current
07022     CARRIAGE: Carriage control board error: over temperature
11005     CABLE: External Chiller/Debris Blower sensor cable disconnected.
11575     CABLE: Operator Interface not connected
11576     CABLE: Pushbutton not connected
11582     CABLE: CD-D-BP: Carriage Drive Digital
11583     CABLE: CD-A-BP: Carriage Drive Analog
11584     CABLE: CM-CDB: Carriage Drive to Motor
11585     CABLE: AL Air Valves not connected (J21)
11586     CABLE: Picker Sensors not connected (J11)
11587     CABLE: Table Sensors not connected (J6)
11588     CABLE: TEE-AL stepper drive cbl (J17)
11593     CABLE: Sensors not connected (J7)
11594     CABLE: Air Valves not connected (J20)
11595     CABLE: LR plate sensor not connected (J3)
11596     CABLE: Fly-off cable not connected (J2)
11597     CABLE: Temp Sensors not connected (J13)
11598     CABLE: TEE-AL warning lamp cbl (J24)
11599     CABLE: TEE-AL cover lock cbl (J26)
12701     POWER: TEE +24V
15050     ALE: in reset condition
15051     ALE: ALE board not installed
15053     ALE: Autoloader operation aborted
15055     ALE: software error!!
15068     ALE: move clamps to park position, then select RESUME
15073     ALE: trailing edge clamp status conflict, setting te state flag to<0|1>. ( "1" indicates "on drum", "0" indicates "on tec backbone" )
15085     ALE: roller on drum
15086     ALE: leading-edge actuator on drum
15087     ALE: trailing-edge actuator on drum
15163     ALE: Plate size in bay <bay#> is zero. Load bay to set size.
15170     ALE: remove plate from picker
15171     ALE: remove plate from unload table
15176     ALE: no plate detected on unload vacuum cups
15177     ALE: picker vacuum below threshold
15178     ALE: no plate on picker
15179     ALE: no plate on unload table
15250     ALE: timeout waiting for load button to be pressed
15251     ALE: plate not detected on load ramp
15252     ALE: plate larger than expected
15253     ALE: plate smaller than expected
15254     ALE: remove plate detected on load ramp
15259     ALE: load ramp is tilted into drum no-fly zone
15285     ALE: Plate smaller than expected. Device is unable to unload this plate safely. Pleaseremove plate from drum.
15286     ALE: Plate larger than expected. To try another plate, press Resume.
15287     ALE: Plate smaller than expected. To try another plate, press Resume.
15300     ALE: Separator timed out moving out
15301     ALE: Picker timed out moving [up!down!out]
15302     ALE: Separator obstructed by picker
15303     ALE: Picker obstructed by separator|picker in
15304     ALE: Unload Table timed out moving up|down
15305     ALE: Unload cups rotated, can't move unload carriage
15306     ALE: Unload carriage not in safe position to rotate cups
15307     ALE: Load ramp timed out moving out
15308     ALE: Unload Cups timed out moving in
15309     ALE: Rotator move timed out moving to rotated|unrotated position
15310     ALE: AL SW error: invalid parameter file <filename> line <line number>
15311     ALE: Plate still on unload table, can't unload
15312     ALE: Please remove plate from unload table
15313     ALE: Please close plate cover
15314     ALE: Please put plate cover in manual bypass position
15315     ALE: Traveller rotate position sensor is already high (sensor may be broken)
15316     ALE: Multiple plates on drum (or head out of alignment by %d microns). Cancelimage to unload plate.
15317     ALE: Autoloader is suspended and cannot accept new commands.
15318     ALE: Manual bypass loading is not supported on this machine.
15319     ALE: Plates are sticking together. Please open the plate cover and separate the plates.Press RESUME to continue.
15320     ALE: STEP : axis 2 communication error
15321     ALE: STEP : axis 2 is busy
15322     ALE: STEP : axis 2 initialization error
15323     ALE: STEP : axis 2 not initialized
15324     ALE: STEP : axis 2 SW error: invalid PARAMETER
15325     ALE: STEP : axis 2 aborted while moving
15326     ALE: STEP : axis 2 SW error: invalid STATE
15327     ALE: STEP : axis 2 distance out of range
15328     ALE: STEP : axis 2 timed out while aborting
15329     ALE: STEP : axis 2 distance must be positive
15330     ALE: STEP : axis 2 already moving
15331     ALE: STEP : axis 2 HOME limit switch is active
15332     ALE: STEP : axis 2 AWAY limit switch is active
15333     ALE: STEP : axis 2 timed out while homing
15334     ALE: STEP : axis 2 timed out while moving
15335     ALE: Please close access door
15336     ALE: Timeout waiting for QSPI system to initialize, stepper drive task startup failed
15340     ALE: Punch communication error: error sending dataPunch communication error: Timeout waiting for punch responsePunch communication error: Timeout waiting for punch status informationPunch communication error: unknown information messagePunch communication error: Timeout waiting for punch error messagePunch communication error: unknown error informationPunch communication error: unexpected status signal
15341     ALE: Error: request to rotate plate when rotator not properly installed
15342     ALE: Error: request to punch plate when punch not properly installed
15343     ALE: Punch reported status error: punch chip drawer requires emptyingPunch reported status error: punch heads require oilingPunch reported status error: low air pressurePunch reported status error: punch not in automatic mode, check keypad if present
15344     ALE: Punch reported mechanical error: plate still in punchPunch reported mechanical error: problem moving punch inlayPunch reported mechanical error: problem moving punch stopPunch reported mechanical error: problem raising or lowering punch inlayPunch reported mechanical error: problem with punch plate sensorPunch reported mechanical error: punch could not find plate edge
15345     ALE: Punching error: plate did not register on punchPunching error: plate not free of punchPunching error: Timeout waiting for plate to passPunching error: Timeout waiting for punch to be readyPunching error: Timeout waiting for side registrationPunching error: Timeout waiting for punching to completePunching error: Timeout waiting for inlay to move downPunching error: Timeout waiting for plate to registerPunching error: Plate still touching stops
15346     ALE: Punch status is okay
15347     ALE: The punch is still waiting for the last plate to leave.
15348     ALE: Picker wrist sensor isn't working
15349     ALE: Picker wrist cylinder is faulty
16064     IMAGE: Image update received unexpectedly
16066     IMAGE: Reject plate - unloading from drum
22450     ALE2: Plate too small to run through the processor, please remove plate from unload table
22451     ALE2: Plate too large to fit into the processor, please remove plate from unload table

Base Trendsetter Errors

This content is generated by scripts that pull information directly from Firmware Engineering's support site. The scripts were last run: 16 Jul 2008 17:30:07

Number Error Message
00000     MISC:
00001     MISC: Reserved
00002     MISC: Reserved
00003     MISC: Reserved
00004     MISC: Reserved
00005     MISC: Reserved
00006     MISC: Reserved
00007     MISC: Reserved
00020     MISC: Specified test is not defined
00021     MISC: Workstation communications lost
00030     MISC: Requested command is not defined
00100     MISC: MPE Code checksum is faulty
00101     MISC: LCA module checksum is faulty
00102     MISC: LCA module incompatable format
00103     MISC: Module not found in version list
00104     MISC: Firmware module checksum is faulty
00105     MISC: Error opening firmware module
00106     MISC: Invalid or unneeded code bundled with firmware
00107     MISC: Missing required code in the firmware bundle
00108     MISC: Product version not found in version list
00109     MISC: Invalid version of overwriting pattern
00200     MISC: Code bank selected for loadingis current code bank
00201     MISC: Flash memory program failed
00202     MISC: Address <hex address> out of memory bank range
00203     MISC: Unsupported memory type detected
00204     MISC: Flash memory erase failed
00500     MISC: Temperature log: Engine = <Celcius x 10> Leadscrew = <Celcius x 10>
00501     MISC: Password not set!
00502     MISC: NVS modified and saved, but not backed up!
00511     MISC: Dongle not responding
00512     MISC: Config: %s %s owner %s
01000     RESET: cause unknown
01001     RESET: induced by test submodule
01002     RESET: induced by RESET opcode, possible warm reset requested at monitor
01004     RESET: induced by loss of clock
01016     RESET: induced by halt monitor
01032     RESET: induced by software watchdog, possible cold reset requested at monitor
02000     NVS: checksum error in <NVS subsystem> calibration block
02040     NVS: checksum error in <NVS subsystem> configuration block
02080     NVS: checksum error in mode <number> table
02200     NVS: low battery in NVS detected
02201     NVS: NVS automatically upgraded to version 2
02202     NVS: subscan size nvs config parameter is invalid
03000     WSCOMM: All faults cleared
03001     WSCOMM: Invalid command letter
03002     WSCOMM: Parameter syntax error
03003     WSCOMM: Defined WS command is currently unsupported
03004     WSCOMM: Character pacing timeout, WS transmitting too slowly
03005     WSCOMM: too many characters in command string
03006     WSCOMM: Could not open serial communications interface for workstation
03007     WSCOMM: Resume or clear received when not suspended
03008     WSCOMM: Command received for idle image ID
03009     WSCOMM: Specified image ID is already active
03010     WSCOMM: Maximum active image commands surpassed
03011     WSCOMM: Resolution specified is not available
03012     WSCOMM: Already aborting
03014     WSCOMM: Abort received when no command active
03015     WSCOMM: Already imaging
03016     WSCOMM: Recorder is flushing, can't accept new commands
03017     WSCOMM: Door is open
03018     WSCOMM: Door is closed
03019     WSCOMM: ABORT switch on
03020     WSCOMM: ABORT switch off
03021     WSCOMM: Operation aborted at recorder - check that abort switch is released
03022     WSCOMM: Operation aborted by workstation
03023     WSCOMM: ABORT complete
03024     WSCOMM: Abort request not heeded within timeout, possible hung subsystem
03025     WSCOMM: Task(s) <task codes> did not finish initializing on time
03026     WSCOMM: Operation preempted
03027     WSCOMM: Cassette bay door open
03028     WSCOMM: Cassette bay door closed
03047     WSCOMM: Resolution does not exist
03048     WSCOMM: Image too wide for plate
03055     WSCOMM: Workstation software error - Invalid packet number
03056     WSCOMM: Workstation software error - Invalid total packets number
03057     WSCOMM: Workstation software error - Out of sequence packet received
03058     WSCOMM: Workstation software error - Invalid packet length
03059     WSCOMM: Workstation software error - Invalid Media Imaging Mode ID (MIMID)
03060     WSCOMM: Packet fails CRC check
03061     WSCOMM: Total packet data exceeding firmware buffer capacity
04001     MSG: Command parameter error
04002     MSG: Parameter is out of range
04003     MSG: Defined command is currently unsupported
04004     MSG: Requested test pattern not defined
04005     MSG: <subsystem> is already reserved
04006     MSG: Reserved message in message pool
04007     MSG: Task releasing message owned by another task
04008     MSG: Task releasing unreserved message
04009     MSG: Task sending message owned by another task
04010     MSG: Task sending unreserved message
04011     MSG: Task received message that was not sent
04012     MSG: Reserved string in string pool
04013     MSG: Task releasing unreserved string
04014     MSG: Task releasing string owned by another task
04015     MSG: Task reserving released string
04016     MSG: <task name> timed out while waiting for command <hex command code>
04017     MSG: <task name> received an invalid command (command = <hex command code>)
04018     MSG: Wrong number of parameters
04019     MSG: Inactive list sent
04020     MSG: Unexpected list type sent
04021     MSG: Invalid list entry number sent - Possible version incompatabilities
04022     MSG: Plot mode not specified before plot parameters
04024     MSG: Task received msg with unexpected id (code = %X)
04028     MSG: suspended - waiting for Resume or Clear
04029     MSG: plate thickness too large
04030     MSG: one or both plate dimensions too large
04031     MSG: media type out of range
04032     MSG: one or both plate dimensions too small
04034     MSG: media %d not supported
06000     DRUM: Timeout on drum operation
06001     DRUM: Illegal command state machine state
06002     DRUM: Timeout waiting for drum move
06003     DRUM: Received invalid command
06004     DRUM: drum not initialized - can't execute that command
06005     DRUM: Unexpected status returned from function
06006     DRUM: Timeout during active braking
06007     DRUM: Timeout on velocity settling
06008     DRUM: Timeout on velocity acceleration
06009     DRUM: Sample interrupt failure
06011     DRUM: Servo amp fault
06012     DRUM: Cable from motherboard to drum servo amp not detected
06013     DRUM: Index not detected
06014     DRUM: Extra Tach A pulse detected
06015     DRUM: Missing Tach A pulse
06016     DRUM: Extra Tach B pulse detected
06017     DRUM: Missing Tach B pulse
06018     DRUM: Drive direction incorrect - check motor wiring
06019     DRUM: Tach encoder cable not detected
06020     DRUM: Aborted
06021     DRUM: Timeout on hold
06022     DRUM: Motor current exceeded limit
06023     DRUM: Velocity error - drum rotation blocked or PID gain settings wrong
06024     DRUM: Position error is greater than 1000 ticks
06025     DRUM: Hall velocity error - drum rotation blocked or PID gain settings wrong
06026     DRUM: Timeout waiting for TPU hall sensor PW measurement
06027     DRUM: Plate not loaded correctly on drum, obstruction detected below LEC actuator
06028     DRUM: ALE actuators on drum
06029     DRUM: Hall mode overspeed error - possible TPU failure
06030     DRUM: Drum hall velocity does not match encoder velocity to within tolerance.
06031     DRUM: Drum is spinning.
06033     DRUM: Index detected prematurely - clean encoder disc or re-align encoder
06034     DRUM: Drum won't settle with zero torque applied - requires drum cal
06036     DRUM: Drum Position error during Velocity mode, (check acceleration setting)
06037     DRUM: Drum velocity greater than xx rpm in Position mode, possible runaway
06038     DRUM: LCA tick counter annomaly, premature index or spurious counter reset
06039     DRUM: Drum Position error during Velocity mode, (extra index possible cause, check monitor values)
06040     DRUM: Encoder counted extra ticks
06041     DRUM: Index occurred at xx, more than 3 ticks before normal ticks per rotation
06042     DRUM: Hall velocity error - more than 20 percent during drum init.
07000     CARRIAGE: Limit switches reporting carriage is both HOME and AWAY
07001     CARRIAGE: stuck in HOME position
07002     CARRIAGE: stuck in AWAY position
07003     CARRIAGE: unexpectedly arrived at HOME position
07004     CARRIAGE: unexpectedly arrived at AWAY position - image size may have been too large
07005     CARRIAGE: operation timed out
07006     CARRIAGE: timed out while waiting for LCA position
07007     CARRIAGE: position register not accurate
07008     CARRIAGE: LCA's not configured at startup
07009     CARRIAGE: ALE not taken out of reset
07010     CARRIAGE: Unexpected error: 0x%x
07011     CARRIAGE: could not find edge of platecheck that plate size is entered correctly
07012     CARRIAGE: did not reach target speed
07013     CARRIAGE: step synth position register reserved
07015     CARRIAGE: Head Stage is at it's away position, unsafe to move carriage
07016     CARRIAGE: ALE board timed out during carriage position read
07017     CARRIAGE: Carriage state error. Current state: <description>, jog_count = <n> JOG = <number> PLOT = <number>
07018     CARRIAGE: Carriage illegal dest. Current %lu, Dest %lu Stop Dist %lu
07019     CARRIAGE: Specified Speed exceeds maximum of %lu
07020     CARRIAGE: Carriage control board error: cable not detected or undervoltage
07021     CARRIAGE: Carriage control board error: over current
07022     CARRIAGE: Carriage control board error: over temperature
08000     PROC: Processor not present or turned off
08001     PROC: Processor is not ready
08002     PROC: Processor fault requires immediate attn.
08003     PROC: Processor warning will need attention
08004     PROC: Processor type unknown
08005     PROC: Illegal processor number used
10012     HARDWARE: Carriage limit switch
10019     HARDWARE: ALE is not plugged in
10020     HARDWARE: DPE is not plugged in
10022     HARDWARE: MPE LCA's not configured at startup
10023     HARDWARE: DPE will not initialize, may be stuck in reset
10025     HARDWARE: DPE LCA's not configured at startup
10026     HARDWARE: Incorrect DPE version installed
10050     HARDWARE: RAM DAC Incrementing Address Test fail - Address = <fault address>, Write data = <hex data>, Readdata = <hex data>
10051     HARDWARE: DPE failure - dpath control write = <hex data>, read = <hex data>
10060     HARDWARE: External Debris Blower Filters Not Present
10061     HARDWARE: External Debris Blower Filters Full
10062     HARDWARE: External Debris Blower Filters Almost Full (Vacuum Level %d is below %d)
10063     HARDWARE: External Debris Blower System Blocked (Vacuum Level %d is above %d)
10064     HARDWARE: External Debris Blower Not Connected or Filters Full (Vacuum Level %d is below %d)
10065     HARDWARE: DBlower Filter Fault.
11000     CABLE: HA-BP cbl, Carriage Home/Away
11002     CABLE: EH-BP: Exposure Head - Backplane
11003     CABLE: TE-BP: Tach Encoder - Backplane
11004     CABLE: MD-BP: Drum Motor - Backplane
11005     CABLE: External Chiller/Debris Blower sensor cable disconnected.
11504     CABLE: SPR-BP
11575     CABLE: Operator Interface not connected
11576     CABLE: Pushbutton not connected
11582     CABLE: CD-D-BP: Carriage Drive Digital
11583     CABLE: CD-A-BP: Carriage Drive Analog
11584     CABLE: CM-CDB: Carriage Drive to Motor
11593     CABLE: Sensors not connected (J7)
11594     CABLE: Air Valves not connected (J20)
11595     CABLE: LR plate sensor not connected (J3)
11596     CABLE: Fly-off cable not connected (J2)
11597     CABLE: Temp Sensors not connected (J13)
12000     POWER: ALE +12V
12001     POWER: ALE -12V
12002     POWER: Carriage power
12006     POWER: Carriage Amp Fault
12007     POWER: Exposure Head power
12008     POWER: Drum Amp Fault
12701     POWER: TEE +24V
13000     EHBOOT: internal message timeout
13001     EHBOOT: datalink terminated the program sequence prematurely
13002     EHBOOT: format error detected during data transfer
13003     EHBOOT: sumcheck error detected during data transfer
13004     EHBOOT: datalink programming sequence taking too long
13005     EHBOOT: LOADER echo mismatch during bootstrap sequence
13006     EHBOOT: LOADER not echoed during bootstrap sequence
13007     EHBOOT: no break detected after forcing head into bootstrap mode
13008     EHBOOT: cannot perform requested operation, no LOADER present
13009     EHBOOT: LOADER prompt for next primitive did not arrive
13010     EHBOOT: communications error
13011     EHBOOT: failed to program location <hex data> with data <hex data>
13012     EHBOOT: failed to erase device, stopped at location <hex data>
13013     EHBOOT: failed to respond to programming command
13014     EHBOOT: Timeout on byte <byte #> while waiting for exposure head to complete response string
13015     EHBOOT: ENQ expected and not received
13016     EHBOOT: ACK expected and not received
13017     EHBOOT: incorrect response length
13018     EHBOOT: incorrect version length
13019     EHBOOT: incorrect version response in byte <byte #>
13020     EHBOOT: incorrect response address
13021     EHBOOT: incorrect response data
14000     SAT: Satellite error cleared
14002     SAT: Unknown Satellite Output Register: <hex number>
14003     SAT: Satellite SW corrupted Buffer
14004     SAT: Buffer Restore error during Output Command
14050     SAT: QSPI error during configuration
14051     SAT: Timeout during SPI enable
14052     SAT: Timeout during QSPI disable
14053     SAT: Timeout during SPI execution
14054     SAT: SPI Mode Fault error
14055     SAT: QSPI Update Watchdog timeout
14056     SAT: <Satellite Board> Error: <Output Name>
14057     SAT: Error Detection Error: Address <address>, Bit = <bit number>
14100     SAT: Temperature Filter Error: Out of range
14101     SAT: LUE Analog testpoint exceeded allowed maximum
14102     SAT: LUE Analog testpoint exceeded allowed minimum
14103     SAT: Engine Frame temperature out of range
14104     SAT: Engine Leadscrew temperature out of range
14105     SAT: Spare sensor 0 temperature out of range
14106     SAT: Spare sensor 1 temperature out of range
14107     SAT: Timeout waiting for conveyor roller speed to update
14108     SAT: Timeout waiting for conveyor belt speed to update
14150     SAT: Cassette Bay <bay number> invalid, autoloader currently configured for <max> bays
14151     SAT: Cassette Bay <bay number> Error: <device>
14200     SAT: PPE Analog testpoint exceeded allowed maximum
14201     SAT: PPE Analog testpoint exceeded allowed minimum
14202     SAT: Software error: invalid lamp state %d in sat_set_lamp_state()
14203     SAT: Software error: invalid image task state %d in sat_update_lamps()
15059     ALE: Autoloader is not initialized, possibly due to an opened door
15062     ALE: plate loaded incorrectly, remove plate from drum
15068     ALE: move clamps to park position, then select RESUME
15071     ALE: remove plate from drum
15072     ALE: remove plate partially on drum
15073     ALE: trailing edge clamp status conflict, setting te state flag to<0|1>. ( "1" indicates "on drum", "0" indicates "on tec backbone" )
15074     ALE: trailing edge clamps failed to unlock
15075     ALE: trailing edge clamps failed to lock
15076     ALE: trailing edge clamps not on actuator
15077     ALE: trailing edge clamps already on actuator, possible sensor or software error.
15078     ALE: no plate on drum
15079     ALE: timeout moving leading edge cylinder
15080     ALE: timeout moving trailing edge cylinder
15082     ALE: timeout moving roller cylinder
15085     ALE: roller on drum
15086     ALE: leading-edge actuator on drum
15087     ALE: trailing-edge actuator on drum
15250     ALE: timeout waiting for load button to be pressed
15251     ALE: plate not detected on load ramp
15252     ALE: plate larger than expected
15253     ALE: plate smaller than expected
15254     ALE: remove plate detected on load ramp
15259     ALE: load ramp is tilted into drum no-fly zone
15281     ALE: Please load plate
15283     ALE: Please unload plate
16005     IMAGE: update received after load started
16006     IMAGE: task received incorrect ID
16007     IMAGE: Inactive image task received image update
16008     IMAGE: Total mainscan shift less than or equal to zero
16009     IMAGE: Total subscan shift less than zero
16010     IMAGE: Total mainscan shift too large
16011     IMAGE: PLL is not able to track drum motion
16012     IMAGE: PLL was not able to maintain drum motion tracking
16013     IMAGE: Specified \"around drum\" image size too large
16018     IMAGE: exposure too low
16021     IMAGE: mainscan length must be a multiple of 16
16022     IMAGE: command received when already suspended
16023     IMAGE: plate exposed by open door
16025     IMAGE: Stroke must be flat when calibrating scorr
16026     IMAGE: Scorr must be initialized in current mode before calibrating
16027     IMAGE: TPG not idle after imaging, DPE reset
16028     IMAGE: Series plot completed
16030     IMAGE: Series strip width is set to zero
16038     IMAGE: Total number of retraces: <retraces>
16050     IMAGE: DPE orthog slope less than 0, check plate rotation
16051     IMAGE: DPE orthog slope larger than max, check plate rotation
16054     IMAGE: Attempt to image B-side before A-side
16056     IMAGE: Plate imaging has begun
16068     IMAGE: Unable to initialize plot for mode set to 0 DPI
16073     IMAGE: Negative media (inverted data) requires FDPE
17046     HEAD: multiple edges detected - verify image position
17501     HEAD: temperature out of range
17502     HEAD: value out of range
17503     HEAD: missing laser on parameters
17504     HEAD: attempted write blocked
17505     HEAD: failure to write to memory
17506     HEAD: unsupported message
17507     HEAD: message length incorrect
17508     HEAD: invalid control message
17509     HEAD: operation was aborted
17532     HEAD: no more room in mailbox
17533     HEAD: ran out of buffers
17534     HEAD: all retries failed on chnl 0
17535     HEAD: all retries failed on chnl 1
17536     HEAD: sync lost on chnl 0
17537     HEAD: sync lost on chnl 1
17548     HEAD: CONFIG register incorrect
17549     HEAD: flash memory checksum error
17550     HEAD: LCA won't init for reprogram
17551     HEAD: LCA won't admit being loaded
17552     HEAD: SRAM memory check failure
17596     HEAD: software error
17597     HEAD: LCA config unavailable
17692     HEAD: Light level too low for Beam Pointing
17693     HEAD: Timeout waiting for LASER OK
17694     HEAD: Light valve high voltage fault
17695     HEAD: LV Positive 12V fault (bipolar)
18017     LASER: Cannot continue, laser is not ready
19000     PDB: Air Supply Below Threshold
21000     SCSI: SCSI bus reset while imaging
21001     SCSI: SCSI parity error while imaging, check plate for artifacts
21002     SCSI: SCSI driver error, invalid initiator
21003     SCSI: SCSI Driver Error, line <line number>
21004     SCSI: SCSI asynchronous transfer requested, line <line number>
21005     SCSI: timed out waiting for SCSI complete
30000     TPG: memory overflow
30001     TPG: too many scans
30002     TPG: write to closed scan
30003     TPG: write to unopened scan
30004     TPG: write to undefined scan
30005     TPG: close of closed scan
30006     TPG: close of unopen scan
30007     TPG: open of NULL scan
30008     TPG: Undefined pattern number, use "list pattern"
30009     TPG: Call with NULL pattern struct
30010     TPG: Pattern write call error
30011     TPG: Too many cells in pattern
30012     TPG: timed out waiting for stripe to complete
31002     LCA: DONE signal stuck low while programming
31003     LCA: READY signal stuck low while programming
31004     LCA: did not accept programming data
31006     LCA: INIT signal stuck low while programming
31007     LCA: INIT signal stuck high while programming
31008     LCA: Required LCA file is not in firmware
31009     LCA: Required LCA master file is not in firmware
31010     LCA: Length of LCA diff file does not match master
32200     SW: Ink Key buffers out of synch
32201     SW: Image shutdown error
32202     SW: NCO update timeout
32203     SW: Resolution mode not defined
32301     SW: Unknown ID code in firmware directory
32302     SW: undefined subsystem in NVS list
32401     SW: Could not open console interface for serial communications
32403     SW: Could not open head interface for serial communications
32404     SW: Could not open laser interface for serial communications
32450     SW: Out of memory
32480     SW: WS data list unexpectedly in use
32481     SW: WS command pattern incorrect
32490     SW: AL Sched: pick sync error
32491     SW: AL Sched: unload sync error
32492     SW: AL Sched: load sync error
32493     SW: AL Sched: process sync error
32500     SW: Unexpected SW failure - general exception
32600     SW: executive call failed
32601     SW: executive call tsk_create() failed
32602     SW: executive call tsk_delete() failed
32603     SW: executive call tsk_suspend() failed
32604     SW: executive call tsk_resume() failed
32605     SW: executive call tsk_set_priority() failed
32606     SW: executive call mbx_create() failed
32607     SW: executive call mbx_delete() failed
32608     SW: executive call mbx_send() failed
32609     SW: executive call mbx_receive() failed
32610     SW: executive call mbx_flush() failed
32611     SW: executive call buf_alloc() failed
32612     SW: executive call buf_free() failed
32613     SW: executive call tmr_create() failed
32614     SW: executive call tmr_delete() failed
32615     SW: executive call pip_create() failed
32616     SW: executive call pip_delete() failed
32617     SW: mbx_send failed, NULL mailbox
32618     SW: mbx_send failed, mailbox full
32700     SW: all tasks suspended
32701     SW: Unexpected message in mailbox <mailbox name>, message code <hex message code>
32702     SW: message buffer request failed
32703     SW: message buffer release failed
32704     SW: string buffer request failed
32705     SW: string buffer release failed
32706     SW: unexpected case - file:<filename> line:<line number>
32707     SW: image command received by active task
32708     SW: procedure call has invalid parameters
32709     SW: status mask has duplicate flags defined
32710     SW: Invalid status code for this command code: <hex command code>
32711     SW: Unexpected message type for this command. type: <hex message type>
32766     SW: Non-specific error