| Component | Rubber Boot Insulator | ||||||||||||||||||||
| Problem | A rubber boot insulator, part #18-3243, has been found to be electrically conductive in batches delivered to CreoScitex since August 16, 1999. This causes a safety hazard to service personnel, and can also start fires. | ||||||||||||||||||||
| Solution | Replace part #18-3243 with new approved part #18-3355 which uses silicone instead of rubber. | ||||||||||||||||||||
| Procedure | See D788 upgrade procedure . | ||||||||||||||||||||
| Parts Needed | Three upgrade kits have been created:
05-0166 kit,upgrade,ECO D788, rubber boot, TS 05-0172 kit,upgrade,ECO D788, rubber boot, FX1 05-0173 kit,upgrade,ECO D788, rubber boot, TSV BOM |
||||||||||||||||||||
| Release Date | Sept 2000 | ||||||||||||||||||||
| Priority | ASAP | ||||||||||||||||||||
| Contact | Ian Skinner | ||||||||||||||||||||