Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order D788


Applies to
Trendsetter TS3/8 from S330 to S389
Proofsetter TS3/8 PRO47 to PRO90
Trendsetter TS4 from TF0013
TrendsetterTS8 up to TE047
Proofsetter TS8 up to PX020
TS2637 from TN001
Thermoflex FX09 to FX24
TSVLF B238 to B390
TS400 All
Note: upgrading the Debris Removal Cabinets, 11-0579 and 11-0594, is critically important.
Component Rubber Boot Insulator
Problem A rubber boot insulator, part #18-3243, has been found to be electrically conductive in batches delivered to CreoScitex since August 16, 1999. This causes a safety hazard to service personnel, and can also start fires.
Solution Replace part #18-3243 with new approved part #18-3355 which uses silicone instead of rubber.
Procedure See D788 upgrade procedure .
Parts Needed Three upgrade kits have been created:

05-0166 kit,upgrade,ECO D788, rubber boot, TS

05-0172 kit,upgrade,ECO D788, rubber boot, FX1

05-0173 kit,upgrade,ECO D788, rubber boot, TSV BOM

Release Date Sept 2000
Priority ASAP
Contact Ian Skinner

Back to top


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.