Trendsetter VLF |
||
Component |
Balance weights |
||
Error |
15844 ALE: Timeout moving balance weight actuator |
||
Symptoms |
The balance weight cylinder does not move within the time specified by "altim bct". |
||
Cause |
The value of the nvs parameter 'altim bct' (balance cylinder timeout) may be low, the balance cylinder extend/retract sensors may not be working properly, or the air/electrical connections may be faulty. | ||
Solution |
Move the drum balance cylinder "act bal1 on/off" or "act bal2 on/off" to verify that the sensor sees the cylinder movement. If the system does not sense that the cylinder is moving, check its actual behaviour by opening the door and looking at it (if servicing remotely, ask the operator to check).
|
||