Component |
SCSI cable terminations. |
|---|
|
Problem |
The basic problem has to do with poor high frequency termination of the shields of SCSI and serial cables to the imaging device. |
|---|
|
Symptoms |
|
|---|
|
Causes and |
The communication cabling from the Creo
workstation to the output device is very critical to the
performance of the system. The SCSI cable is a braid shielded
68-conductor cable that transfers imaging data from the
workstation to the output device. The shield protects the data
from noisy environments by blocking any radio frequency
disturbances from corrupting the data. To ensure performance the
shield MUST be properly terminated to chassis at the workstation
as well as the output device. The serial communication cables
for the workstation as well as the diagnostics cable follow the
same process. It is essential that these cables are the cables
specified by Creo as lower quality cables may not have the
shielding effectiveness or proper termination required.
If a customer system exhibits these errors check the following:
All Creo recorders are certified to comply with the emission standards and the immunity standards. However, individual machines may be more sensitive to RF fields and individual environments may be more severe than what we tested for. |
|---|
|