Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Workstation hangs and reports SCSI errors (all VLFs)


Applies to

 
  • VLF Trendsetter
  • VLF Platesetter

Component

 

Workstation


Problem

 

During plotting, SCSI errors are logged on the workstation and imaging stops.


Causes and solutions

  1. Check the MPE board, as there could be a PLL fault.
See General VLF Drum Drive, Encoder, and PLL troubleshooting.

2. If the customer is using Alpha 500 WS and Barco FastRip, the Barco FastRip may be writing spool data to the system folder. When the system drive fills up, the workstation reports a SCSI error. Check the configuration of the Barco FastRip.


Technical Contact(s)
 

Carl Van Maarseveen
Annacis local 3470

Michael_Van_den_Putte
Application Support, Creo Europe


Date Submitted

8 Aug 2000


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.