Chiller shuts down when debris unit starts up


Product

 
  • Trendsetter VLF
  • Trendsetter VLF Autoloader

Component

 

Chiller


Symptoms

 

The chiller shuts down when the debris unit starts. The chiller displays 8888 on the front panel.


Cause

 

A cable inside the Trendsetter, 10-3852A, has a resistor on the +24V line to the chiller and UDRC interface signals. When the UDRC and chiller are both running, the +24v drops to about 3-5v because of the resistor. This is marginal for the chiller interface and it will shut down. When the UDRC stops, the chiller starts up again.


Solution

 

Replace the 10-3852A cable with 10-3852B. The B version has the resistor omitted.


Technical contact(s)
 

Al Edge

Submitted by
 

Al Edge

Date submitted
 

06 Sep 2005