If the plot shuts down with an
"external debris blower system blocked" error message on a
VLF Trendsetter or VLF Platesetter that has a debris removal system
installed, it may be caused by a defective pressure sensor board
(10-4641A).
|
Cause |
Some pressure sensor boards have been assembled incorrectly. |
Solution |
Check the orientation of voltage regulator
IC U2 on the pressure sensor board (10-4641A) for the debris removal
system. The location of the pressure sensor board is shown in Figure
2 (VLF Trendsetter) and Figure 3 (VLF
Platesetter).
Figure 1: Pressure Sensor Board (10-4641A)
Figure 2: Typical location of pressure
sensor board on VLF TS / VLF PS
Figure 3: Location of pressure sensor board on earlier VLF Platesetters |
See also |
72-3248A, VLF Platesetter/Trendsetter UDRC-B Installation/Upgrade, 40W, V-head |
| Submitted by | Dwayne Brandt (Annacis local 3931) |
| Date | July 5, 2000 |