Number Error Message
00000     MISC:
00001     MISC: Reserved
00002     MISC: Reserved
00003     MISC: Reserved
00004     MISC: Reserved
00005     MISC: Reserved
00006     MISC: Reserved
00007     MISC: Reserved
00020     MISC: Specified test is not defined
00021     MISC: Workstation communications lost
00030     MISC: Requested command is not defined
00100     MISC: MPE Code checksum is faulty
00101     MISC: LCA module checksum is faulty
00102     MISC: LCA module incompatable format
00103     MISC: Module not found in version list
00104     MISC: Firmware module checksum is faulty
00105     MISC: Error opening firmware module
00106     MISC: Invalid or unneeded code bundled with firmware
00107     MISC: Missing required code in the firmware bundle
00108     MISC: Product version not found in version list
00109     MISC: Invalid version of overwriting pattern
00200     MISC: Code bank selected for loadingis current code bank
00201     MISC: Flash memory program failed
00202     MISC: Address <hex address> out of memory bank range
00203     MISC: Unsupported memory type detected
00204     MISC: Flash memory erase failed
00500     MISC: Temperature log: Engine = <Celcius x 10> Leadscrew = <Celcius x 10>
00501     MISC: Password not set!
00502     MISC: NVS modified and saved, but not backed up!
00511     MISC: Dongle not responding
00512     MISC: Config: %s %s owner %s
01000     RESET: cause unknown
01001     RESET: induced by test submodule
01002     RESET: induced by RESET opcode, possible warm reset requested at monitor
01004     RESET: induced by loss of clock
01016     RESET: induced by halt monitor
01032     RESET: induced by software watchdog, possible cold reset requested at monitor
02000     NVS: checksum error in <NVS subsystem> calibration block
02040     NVS: checksum error in <NVS subsystem> configuration block
02080     NVS: checksum error in mode <number> table
02200     NVS: low battery in NVS detected
02201     NVS: NVS automatically upgraded to version 2
02202     NVS: subscan size nvs config parameter is invalid
03000     WSCOMM: All faults cleared
03001     WSCOMM: Invalid command letter
03002     WSCOMM: Parameter syntax error
03003     WSCOMM: Defined WS command is currently unsupported
03004     WSCOMM: Character pacing timeout, WS transmitting too slowly
03005     WSCOMM: too many characters in command string
03006     WSCOMM: Could not open serial communications interface for workstation
03007     WSCOMM: Resume or clear received when not suspended
03008     WSCOMM: Command received for idle image ID
03009     WSCOMM: Specified image ID is already active
03010     WSCOMM: Maximum active image commands surpassed
03011     WSCOMM: Resolution specified is not available
03012     WSCOMM: Already aborting
03014     WSCOMM: Abort received when no command active
03015     WSCOMM: Already imaging
03016     WSCOMM: Recorder is flushing, can't accept new commands
03017     WSCOMM: Door is open
03018     WSCOMM: Door is closed
03019     WSCOMM: ABORT switch on
03020     WSCOMM: ABORT switch off
03021     WSCOMM: Operation aborted at recorder - check that abort switch is released
03022     WSCOMM: Operation aborted by workstation
03023     WSCOMM: ABORT complete
03024     WSCOMM: Abort request not heeded within timeout, possible hung subsystem
03025     WSCOMM: Task(s) <task codes> did not finish initializing on time
03026     WSCOMM: Operation preempted
03027     WSCOMM: Cassette bay door open
03028     WSCOMM: Cassette bay door closed
03047     WSCOMM: Resolution does not exist
03048     WSCOMM: Image too wide for plate
03055     WSCOMM: Workstation software error - Invalid packet number
03056     WSCOMM: Workstation software error - Invalid total packets number
03057     WSCOMM: Workstation software error - Out of sequence packet received
03058     WSCOMM: Workstation software error - Invalid packet length
03059     WSCOMM: Workstation software error - Invalid Media Imaging Mode ID (MIMID)
03060     WSCOMM: Packet fails CRC check
03061     WSCOMM: Total packet data exceeding firmware buffer capacity
04001     MSG: Command parameter error
04002     MSG: Parameter is out of range
04003     MSG: Defined command is currently unsupported
04004     MSG: Requested test pattern not defined
04005     MSG: <subsystem> is already reserved
04006     MSG: Reserved message in message pool
04007     MSG: Task releasing message owned by another task
04008     MSG: Task releasing unreserved message
04009     MSG: Task sending message owned by another task
04010     MSG: Task sending unreserved message
04011     MSG: Task received message that was not sent
04012     MSG: Reserved string in string pool
04013     MSG: Task releasing unreserved string
04014     MSG: Task releasing string owned by another task
04015     MSG: Task reserving released string
04016     MSG: <task name> timed out while waiting for command <hex command code>
04017     MSG: <task name> received an invalid command (command = <hex command code>)
04018     MSG: Wrong number of parameters
04019     MSG: Inactive list sent
04020     MSG: Unexpected list type sent
04021     MSG: Invalid list entry number sent - Possible version incompatabilities
04022     MSG: Plot mode not specified before plot parameters
04024     MSG: Task received msg with unexpected id (code = %X)
04028     MSG: suspended - waiting for Resume or Clear
04029     MSG: plate thickness too large
04030     MSG: one or both plate dimensions too large
04031     MSG: media type out of range
04032     MSG: one or both plate dimensions too small
04034     MSG: media %d not supported
06000     DRUM: Timeout on drum operation
06001     DRUM: Illegal command state machine state
06002     DRUM: Timeout waiting for drum move
06003     DRUM: Received invalid command
06004     DRUM: drum not initialized - can't execute that command
06005     DRUM: Unexpected status returned from function
06006     DRUM: Timeout during active braking
06007     DRUM: Timeout on velocity settling
06008     DRUM: Timeout on velocity acceleration
06009     DRUM: Sample interrupt failure
06011     DRUM: Servo amp fault
06012     DRUM: Cable from motherboard to drum servo amp not detected
06013     DRUM: Index not detected
06014     DRUM: Extra Tach A pulse detected
06015     DRUM: Missing Tach A pulse
06016     DRUM: Extra Tach B pulse detected
06017     DRUM: Missing Tach B pulse
06018     DRUM: Drive direction incorrect - check motor wiring
06019     DRUM: Tach encoder cable not detected
06020     DRUM: Aborted
06021     DRUM: Timeout on hold
06022     DRUM: Motor current exceeded limit
06023     DRUM: Velocity error - drum rotation blocked or PID gain settings wrong
06024     DRUM: Position error is greater than 1000 ticks
06025     DRUM: Hall velocity error - drum rotation blocked or PID gain settings wrong
06026     DRUM: Timeout waiting for TPU hall sensor PW measurement
06027     DRUM: Plate not loaded correctly on drum, obstruction detected below LEC actuator
06028     DRUM: ALE actuators on drum
06029     DRUM: Hall mode overspeed error - possible TPU failure
06030     DRUM: Drum hall velocity does not match encoder velocity to within tolerance.
06031     DRUM: Drum is spinning.
06033     DRUM: Index detected prematurely - clean encoder disc or re-align encoder
06034     DRUM: Drum won't settle with zero torque applied - requires drum cal
06036     DRUM: Drum Position error during Velocity mode, (check acceleration setting)
06037     DRUM: Drum velocity greater than xx rpm in Position mode, possible runaway
06038     DRUM: LCA tick counter annomaly, premature index or spurious counter reset
06039     DRUM: Drum Position error during Velocity mode, (extra index possible cause, check monitor values)
06040     DRUM: Encoder counted extra ticks
06041     DRUM: Index occurred at xx, more than 3 ticks before normal ticks per rotation
06042     DRUM: Hall velocity error - more than 20 percent during drum init.
07000     CARRIAGE: Limit switches reporting carriage is both HOME and AWAY
07001     CARRIAGE: stuck in HOME position
07002     CARRIAGE: stuck in AWAY position
07003     CARRIAGE: unexpectedly arrived at HOME position
07004     CARRIAGE: unexpectedly arrived at AWAY position - image size may have been too large
07005     CARRIAGE: operation timed out
07006     CARRIAGE: timed out while waiting for LCA position
07007     CARRIAGE: position register not accurate
07008     CARRIAGE: LCA's not configured at startup
07009     CARRIAGE: ALE not taken out of reset
07010     CARRIAGE: Unexpected error: 0x%x
07011     CARRIAGE: could not find edge of platecheck that plate size is entered correctly
07012     CARRIAGE: did not reach target speed
07013     CARRIAGE: step synth position register reserved
07015     CARRIAGE: Head Stage is at it's away position, unsafe to move carriage
07016     CARRIAGE: ALE board timed out during carriage position read
07017     CARRIAGE: Carriage state error. Current state: <description>, jog_count = <n> JOG = <number> PLOT = <number>
07018     CARRIAGE: Carriage illegal dest. Current %lu, Dest %lu Stop Dist %lu
07019     CARRIAGE: Specified Speed exceeds maximum of %lu
08000     PROC: Processor not present or turned off
08001     PROC: Processor is not ready
08002     PROC: Processor fault requires immediate attn.
08003     PROC: Processor warning will need attention
08004     PROC: Processor type unknown
08005     PROC: Illegal processor number used
10012     HARDWARE: Carriage limit switch
10019     HARDWARE: ALE is not plugged in
10020     HARDWARE: DPE is not plugged in
10022     HARDWARE: MPE LCA's not configured at startup
10023     HARDWARE: DPE will not initialize, may be stuck in reset
10025     HARDWARE: DPE LCA's not configured at startup
10026     HARDWARE: Incorrect DPE version installed
10050     HARDWARE: RAM DAC Incrementing Address Test fail - Address = <fault address>, Write data = <hex data>, Readdata = <hex data>
10051     HARDWARE: DPE failure - dpath control write = <hex data>, read = <hex data>
10060     HARDWARE: External Debris Blower Filters Not Present
10061     HARDWARE: External Debris Blower Filters Full
10062     HARDWARE: External Debris Blower Filters Almost Full (Vacuum Level %d is below %d)
10063     HARDWARE: External Debris Blower System Blocked (Vacuum Level %d is above %d)
10064     HARDWARE: External Debris Blower Not Connected or Filters Full (Vacuum Level %d is below %d)
10065     HARDWARE: DBlower Filter Fault.
11000     CABLE: HA-BP cbl, Carriage Home/Away
11002     CABLE: EH-BP: Exposure Head - Backplane
11003     CABLE: TE-BP: Tach Encoder - Backplane
11004     CABLE: MD-BP: Drum Motor - Backplane
11504     CABLE: SPR-BP
12000     POWER: ALE +12V
12001     POWER: ALE -12V
12002     POWER: Carriage power
12006     POWER: Carriage Amp Fault
12007     POWER: Exposure Head power
12008     POWER: Drum Amp Fault
12801     POWER: ALE -2V
13000     EHBOOT: internal message timeout
13001     EHBOOT: datalink terminated the program sequence prematurely
13002     EHBOOT: format error detected during data transfer
13003     EHBOOT: sumcheck error detected during data transfer
13004     EHBOOT: datalink programming sequence taking too long
13005     EHBOOT: LOADER echo mismatch during bootstrap sequence
13006     EHBOOT: LOADER not echoed during bootstrap sequence
13007     EHBOOT: no break detected after forcing head into bootstrap mode
13008     EHBOOT: cannot perform requested operation, no LOADER present
13009     EHBOOT: LOADER prompt for next primitive did not arrive
13010     EHBOOT: communications error
13011     EHBOOT: failed to program location <hex data> with data <hex data>
13012     EHBOOT: failed to erase device, stopped at location <hex data>
13013     EHBOOT: failed to respond to programming command
13014     EHBOOT: Timeout on byte <byte #> while waiting for exposure head to complete response string
13015     EHBOOT: ENQ expected and not received
13016     EHBOOT: ACK expected and not received
13017     EHBOOT: incorrect response length
13018     EHBOOT: incorrect version length
13019     EHBOOT: incorrect version response in byte <byte #>
13020     EHBOOT: incorrect response address
13021     EHBOOT: incorrect response data
14000     SAT: Satellite error cleared
14001     SAT: SPI system not initialized
14002     SAT: Unknown Satellite Output Register: <hex number>
14003     SAT: Satellite SW corrupted Buffer
14004     SAT: Buffer Restore error during Output Command
14050     SAT: QSPI error during configuration
14051     SAT: Timeout during SPI enable
14052     SAT: Timeout during QSPI disable
14053     SAT: Timeout during SPI execution
14054     SAT: SPI Mode Fault error
14055     SAT: QSPI Update Watchdog timeout
14056     SAT: <Satellite Board> Error: <Output Name>
14057     SAT: Error Detection Error: Address <address>, Bit = <bit number>
14100     SAT: Temperature Filter Error: Out of range
14101     SAT: LUE Analog testpoint exceeded allowed maximum
14102     SAT: LUE Analog testpoint exceeded allowed minimum
14103     SAT: Engine Frame temperature out of range
14104     SAT: Engine Leadscrew temperature out of range
14105     SAT: Spare sensor 0 temperature out of range
14106     SAT: Spare sensor 1 temperature out of range
14107     SAT: Timeout waiting for conveyor roller speed to update
14108     SAT: Timeout waiting for conveyor belt speed to update
14150     SAT: Cassette Bay <bay number> invalid, autoloader currently configured for <max> bays
14151     SAT: Cassette Bay <bay number> Error: <device>
14200     SAT: PPE Analog testpoint exceeded allowed maximum
14201     SAT: PPE Analog testpoint exceeded allowed minimum
14203     SAT: Software error: invalid image task state %d in sat_update_lamps()
15062     ALE: plate loaded incorrectly, remove plate from drum
15071     ALE: remove plate from drum
15072     ALE: remove plate partially on drum
15074     ALE: trailing edge clamps failed to unlock
15075     ALE: trailing edge clamps failed to lock
15076     ALE: trailing edge clamps not on actuator
15077     ALE: trailing edge clamps already on actuator, possible sensor or software error.
15078     ALE: no plate on drum
15079     ALE: timeout moving leading edge cylinder
15080     ALE: timeout moving trailing edge cylinder
15082     ALE: timeout moving roller cylinder
15503     ALE: ALE board still in reset
15504     ALE: ALE board not responding
15506     ALE: command already in progress
15507     ALE: Autoloader operation aborted
15508     ALE: Autoloader not initialized
15509     ALE: System air pressure too low!
15510     ALE: Processor channel %d is invalid
15511     ALE: not implemented yet
15520     ALE: %s %d communication error
15521     ALE: %s %d is busy
15522     ALE: %s %d initialization error
15523     ALE: %s %d not initialized
15524     ALE: %s %d SW error: invalid PARAMETER
15525     ALE: %s %d aborted while moving
15526     ALE: %s %d SW error: invalid STATE
15528     ALE: %s %d timed out while aborting
15531     ALE: %s %d HOME limit switch is active
15532     ALE: %s %d AWAY limit switch is active
15533     ALE: %s %d timed out while homing
15534     ALE: %s %d timed out while moving
15535     ALE: please close access door
15539     ALE: engine mount lock cylinders didn't move
15540     ALE: move clamps to park position, then select RESUME
15542     ALE: trailing edge clamps failed to unlock
15543     ALE: trailing edge clamps failed to lock
15544     ALE: trailing edge clamps not on actuator
15545     ALE: trailing edge clamps on actuator
15546     ALE: trailing-edge actuator on drum
15547     ALE: timeout moving trailing edge cylinder
15548     ALE: timeout moving air cylinder
15549     ALE: leading-edge actuator on drum
15550     ALE: timeout moving leading edge cylinder
15551     ALE: timeout moving roller cylinder
15552     ALE: roller on drum
15556     ALE: timeout moving load/unload table
15557     ALE: load/unload table is in the UP position
15558     ALE: load/unload table is in the DOWN position
15559     ALE: timeout moving unload table
15562     ALE: timeout moving exit flap
15563     ALE: cannot move the bay %d tissue compactor, the box lid is in the way
15564     ALE: please pull the plate carrier out of bay %d
15565     ALE: busy with bay %d, cannot process new message code %04Xh
15566     ALE: bay %d safety interlock is open
15567     ALE: timeout loading bay %d
15568     ALE: bay %d is disabled and turned offline
15569     ALE: please close the door on bay %d
15570     ALE: please push the carrier in bay %d all the way in
15571     ALE: bay %d in use
15572     ALE: bay %d is open
15573     ALE: bay %d location not initialized in NVS
15574     ALE: new bay number out of range
15575     ALE: picker inside bay %d, not safe to move
15576     ALE: plate box carrier in bay %d is not in the home position
15577     ALE: bay %d box lid not open
15578     ALE: timeout moving bay %d cassette lid
15579     ALE: missing bay %d cassette lid
15580     ALE: bay %d cassette lid already on grippers
15581     ALE: timeout moving bay %d cassette lid grippers
15582     ALE: timeout moving bay %d shutter cylinder
15583     ALE: bay %d failed to lock
15590     ALE: picker plate-detect microswitch stuck on
15593     ALE: timeout homing bay %d paper sweeper
15594     ALE: timeout while crushing slip-sheets in bay %d
15595     ALE: bay %d paper sweeper is skewed, please move home
15596     ALE: bay %d paper sweeper not responding
15597     ALE: bay %d paper sweeper blocking action, not home or away
15598     ALE: sensors indicate bay %d paper sweeper both home and away
15599     ALE: Please move the bay %d paper sweeper home or away
15600     ALE: plate in bay %d is not metal
15601     ALE: plate in bay %d is metal
15603     ALE: plate loaded incorrectly, remove plate from drum
15604     ALE: plate too small, remove from load ramp
15605     ALE: plate too large or slip sheet attached, remove from load ramp
15606     ALE: plate lost after picking, check inside recorder
15607     ALE: plate on picker, please remove
15608     ALE: no plate on picker or low vac, can't continue
15609     ALE: plate on turtle, please remove
15610     ALE: no plate on turtle or low vac, can't continue
15612     ALE: no plate on load ramp or low vac, can't continue
15613     ALE: plate on unload ramp, please remove
15614     ALE: no plate on unload ramp or low vac, can't continue
15615     ALE: plate stuck on unload ramp
15616     ALE: plate on bridge, please remove
15617     ALE: no plate on bridge, can't continue
15618     ALE: plate on drum, please remove
15619     ALE: no plate on drum, can't continue
15622     ALE: PICK command already in progress
15623     ALE: FETCH command already in progress
15624     ALE: LOAD command already in progress
15625     ALE: UNLOAD command already in progress
15626     ALE: EJECT command already in progress
15627     ALE: EJECT command timed out
15628     ALE: no plate on push-bar or plate size wrong, can't continue
15630     ALE: trailing edge clamp status unknown,\\ possible software or sensor error #%d.
15631     ALE: Picker board not responding or wrong version
15632     ALE: Turtle board not responding or wrong version
15633     ALE: Engine board not responding or wrong version
15634     ALE: Unload Ramp board not responding or wrong version
15636     ALE: Cassette Bay 1 & 2 board not responding or wrong version
15637     ALE: Cassette Bay 3 & 4 board not responding or wrong version
15638     ALE: Cassette Bay 5 & 6 board not responding or wrong version
15640     ALE: picker Z-axis not in handoff position
15641     ALE: turtle W-axis not in position for plate hand-off
15642     ALE: picker Z-axis not HOME
15643     ALE: picker Z-axis not in position for plate grab
15644     ALE: engine_is_installed flag is set to 0!
15660     ALE: Waiting for the bay %d door to close
15661     ALE: Waiting for the bay %d carrier to get home
15662     ALE: Crushing the tissues in bay %d
15663     ALE: Closing the cassette lid in bay %d
15664     ALE: Opening the cassette lid in bay %d
15665     ALE: processor number is invalid, check process[] NVS setting
15666     ALE: ejector motor %d stalled, check for plate in bridge
15667     ALE: timeout moving ejector %d rollers, check hall sensors
15668     ALE: timeout waiting for plate to leave ejector %d
15669     ALE: bridge motor %d stalled, check for plate in bridge
15670     ALE: timeout moving bridge %d rollers
15671     ALE: timeout waiting for plate to leave bridge %d
15672     ALE: PROCESS command aborted, check for plate in bridge
15673     ALE: please lower processor bridge
15674     ALE: please close bridge lid
15675     ALE: please close cassette-bay side access door
15676     ALE: please close front access door
15677     ALE: please close roof access door
15678     ALE: picker in bay %d, select RESUME
15680     ALE: pick could not complete because table is up
15681     ALE: timeout moving tec backbone up or down
15682     ALE: attempt to move backbone with tec locked
15683     ALE: plate expected to cover lower load sensor
15684     ALE: plate expected to be sensed in ejector
15685     ALE: attempt to move table while plate in ejector %d
16005     IMAGE: update received after load started
16006     IMAGE: task received incorrect ID
16007     IMAGE: Inactive image task received image update
16008     IMAGE: Total mainscan shift less than or equal to zero
16009     IMAGE: Total subscan shift less than zero
16010     IMAGE: Total mainscan shift too large
16011     IMAGE: PLL is not able to track drum motion
16012     IMAGE: PLL was not able to maintain drum motion tracking
16013     IMAGE: Specified \"around drum\" image size too large
16018     IMAGE: exposure too low
16021     IMAGE: mainscan length must be a multiple of 16
16022     IMAGE: command received when already suspended
16023     IMAGE: plate exposed by open door
16025     IMAGE: Stroke must be flat when calibrating scorr
16026     IMAGE: Scorr must be initialized in current mode before calibrating
16027     IMAGE: TPG not idle after imaging, DPE reset
16028     IMAGE: Series plot completed
16030     IMAGE: Series strip width is set to zero
16038     IMAGE: Total number of retraces: <retraces>
16050     IMAGE: DPE orthog slope less than 0, check plate rotation
16051     IMAGE: DPE orthog slope larger than max, check plate rotation
16068     IMAGE: Unable to initialize plot for mode set to 0 DPI
17046     HEAD: multiple edges detected - verify image position
17501     HEAD: temperature out of range
17502     HEAD: value out of range
17503     HEAD: missing laser on parameters
17504     HEAD: attempted write blocked
17505     HEAD: failure to write to memory
17506     HEAD: unsupported message
17507     HEAD: message length incorrect
17508     HEAD: invalid control message
17509     HEAD: operation was aborted
17532     HEAD: no more room in mailbox
17533     HEAD: ran out of buffers
17534     HEAD: all retries failed on chnl 0
17535     HEAD: all retries failed on chnl 1
17536     HEAD: sync lost on chnl 0
17537     HEAD: sync lost on chnl 1
17548     HEAD: CONFIG register incorrect
17549     HEAD: flash memory checksum error
17550     HEAD: LCA won't init for reprogram
17551     HEAD: LCA won't admit being loaded
17552     HEAD: SRAM memory check failure
17596     HEAD: software error
17597     HEAD: LCA config unavailable
17692     HEAD: Light level too low for Beam Pointing
17693     HEAD: Timeout waiting for LASER OK
17694     HEAD: Light valve high voltage fault
17695     HEAD: LV Positive 12V fault (bipolar)
18017     LASER: Cannot continue, laser is not ready
19000     PDB: Air Supply Below Threshold
21000     SCSI: SCSI bus reset while imaging
21001     SCSI: SCSI parity error while imaging, check plate for artifacts
21002     SCSI: SCSI driver error, invalid initiator
21003     SCSI: SCSI Driver Error, line <line number>
21004     SCSI: SCSI asynchronous transfer requested, line <line number>
21005     SCSI: timed out waiting for SCSI complete
30000     TPG: memory overflow
30001     TPG: too many scans
30002     TPG: write to closed scan
30003     TPG: write to unopened scan
30004     TPG: write to undefined scan
30005     TPG: close of closed scan
30006     TPG: close of unopen scan
30007     TPG: open of NULL scan
30008     TPG: Undefined pattern number, use "list pattern"
30009     TPG: Call with NULL pattern struct
30010     TPG: Pattern write call error
30011     TPG: Too many cells in pattern
30012     TPG: timed out waiting for stripe to complete
31002     LCA: DONE signal stuck low while programming
31003     LCA: READY signal stuck low while programming
31004     LCA: did not accept programming data
31006     LCA: INIT signal stuck low while programming
31007     LCA: INIT signal stuck high while programming
31008     LCA: Required LCA file is not in firmware
31009     LCA: Required LCA master file is not in firmware
31010     LCA: Length of LCA diff file does not match master
32200     SW: Ink Key buffers out of synch
32201     SW: Image shutdown error
32202     SW: NCO update timeout
32203     SW: Resolution mode not defined
32301     SW: Unknown ID code in firmware directory
32302     SW: undefined subsystem in NVS list
32401     SW: Could not open console interface for serial communications
32403     SW: Could not open head interface for serial communications
32404     SW: Could not open laser interface for serial communications
32450     SW: Out of memory
32480     SW: WS data list unexpectedly in use
32481     SW: WS command pattern incorrect
32490     SW: AL Sched: pick sync error
32491     SW: AL Sched: unload sync error
32492     SW: AL Sched: load sync error
32493     SW: AL Sched: process sync error
32500     SW: Unexpected SW failure - general exception
32600     SW: executive call failed
32601     SW: executive call tsk_create() failed
32602     SW: executive call tsk_delete() failed
32603     SW: executive call tsk_suspend() failed
32604     SW: executive call tsk_resume() failed
32605     SW: executive call tsk_set_priority() failed
32606     SW: executive call mbx_create() failed
32607     SW: executive call mbx_delete() failed
32608     SW: executive call mbx_send() failed
32609     SW: executive call mbx_receive() failed
32610     SW: executive call mbx_flush() failed
32611     SW: executive call buf_alloc() failed
32612     SW: executive call buf_free() failed
32613     SW: executive call tmr_create() failed
32614     SW: executive call tmr_delete() failed
32615     SW: executive call pip_create() failed
32616     SW: executive call pip_delete() failed
32617     SW: mbx_send failed, NULL mailbox
32618     SW: mbx_send failed, mailbox full
32700     SW: all tasks suspended
32701     SW: Unexpected message in mailbox <mailbox name>, message code <hex message code>
32702     SW: message buffer request failed
32703     SW: message buffer release failed
32704     SW: string buffer request failed
32705     SW: string buffer release failed
32706     SW: unexpected case - file:<filename> line:<line number>
32707     SW: image command received by active task
32708     SW: procedure call has invalid parameters
32709     SW: status mask has duplicate flags defined
32711     SW: Unexpected message type for this command. type: <hex message type>
32766     SW: Non-specific error