| Applies to | Trendsetter VLF Autoloader with a MCU | Priority =Next Visit
Reason = Reliability Release date = Nov 2001 |
|
Machines affected |
BA003-005, 011-018, 020-022, 030, 032, 034-041, 043-046, 048, 049, 051, 053, 055-058 & 060 | |
|---|---|---|
|
Component |
MCU Safety Board and cable | |
| Problem | Cable 10-4703A-A
was built incorrectly. At the MCU Safety Interface Board connector
-J3, pins #5 & #6 are reversed as shown below.
|
|
| Solution(s) | Install adapter 10-5064A and replace Safety Interface board 10-4697B. | |
| Parts needed | Kit 05-2033 (cable and board) | |
| Tools needed | n/a | |
| Procedure |
|
|
| Technical contact | Angus Gillon | |