Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order #E465

 

Applies to Trendsetter VLF Autoloader with a MCU Priority =Next Visit
Reason = Reliability
Release date = Nov 2001

Machines affected

BA003-005, 011-018, 020-022, 030, 032, 034-041, 043-046, 048, 049, 051, 053, 055-058 & 060

Component

MCU Safety Board and cable
Problem Cable 10-4703A-A was built incorrectly. At the MCU Safety Interface Board connector -J3, pins #5 & #6 are reversed as shown below.

Solution(s) Install adapter 10-5064A and replace Safety Interface board 10-4697B.
Parts needed Kit 05-2033 (cable and board)
Tools needed n/a
Procedure
  • Check the wiring of pins 5&6 on cable 10-4703A at the J3 connector on the MCU Safety Interface Board.
  • If pins 5&6 are reversed, install the cable adapter 10-5064A and replace the MCU Safety Interface Board 10-4697B.
  • Return the old board to Vancouver to be repaired.
Technical contact Angus Gillon