Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Conveyor does not shut off

Applies to
  • VLF Trendsetter AL

Machines affected All machines.

Error Number None

Component Conveyor (straight or L-type)

Problem The conveyor doesn't shut down once the plate has exited onto the oven conveyor.

Causes and Solutions Cause 1:  Plate exit sensor failed.
Solution a):
  Opto-reflector sensor may have failed in the on position. Check the sensor for damage or wear.
Solution b):  Check that the firmware has detected the sensor signal correctly.
Solution c):  Check that the plate is still on the conveyor. The operator may have manually moved it from the conveyor to the oven.
Solution d):  Check for dirt on the sensor. Clean it with a mild solution of soap and water.
Solution e):  Check that the firmware can read the sensor. If it can't, the operator may have adjusted the height of the sensor. Re-adjust the height until the firmware reads it.

Cause 2:  Connection has failed.
Solution:
  Check for poor connections or faulty wiring between the plate exit sensor and the Genine 4 board.

Cause 3:  Genine board has failed.
Solution:
  Genine 4 driver may have failed.  See VLF Trendsetter AL Genine boards.

Technical contact Andy Ward
Date submitted 28 March 2000
Date modified

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.