| Causes and Solutions |
Cause 1: One or more pusher finger is damaged, and has jammed.
Solution: Replace the damaged pusher finger (there are 2 screws to be removed).
Cause 2: The unload pusher assembly is damaged.
Solution: Replace the entire unload pusher assembly.
- Remove the bottom cover from the unload pusher assembly by unfastening the 8 screws around its edges. Don't remove the 2 screws in the middle.
- Undo the 4 M6 nylock nuts and detach the 2 airlines. Remove the assembly.
- Put the new assembly in position and adjust it. To align it properly, refer to the alignment procedure
|