| Causes and Solutions |
Cause:
There is a possibility that after installing the firmware
versions noted above, the NVS parameter "al_bto" could
be changed to the default value of 5556. When the optical
encoder is being used on these machines, this parameter must be
set to 10,000.
Solution:
- Open a diagnostic window and check the current setting
by typing "set al bto"
- If the current active setting is 5556, change it by
typing "set al bto 10000"
- Save the change by typing "NVS save al bto"
- Load a plate and check the balance weights positioning.
They should be approximately 180° from the trailing
edge clamps. To confirm, enter "drum idle".
The drum should remain stationary or rotate very slowly.
|