Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Failed to Raise SS Picker (error number 22233)


Product

 
  • Trendsetter VLF Autoloader

Machines affected

 

Machines with MPE 1.15 and GENINE 1.16 installed


Component

 

Wedgemaster and optical 'up' sensor


Error

 

22233: Failed to raise ss picker


Symptoms

 

Wedgemaster doesn't go all the way up.


Cause

 

The up sensor tab on the Wedgemaster is failing to interrupt the optical sensor. The tab hits the sensor or bracket instead of passing in front of it.
See the two photos below for the correct motion of the tab past the sensor.


Photo 1: Overview of the Wedgemaster and optical sensor





Photo 2: Close-up view, showing the direction the tab should take past the sensor


Solution

 

Adjust the up sensor tab, using the two adjustable screws on the bracket.


Technical contact(s)
 

Marek Zgrych

Submitted by
 

Bob Wouters

Date submitted
 

04 Apr 2002