Air regulator assembly (SMC) |
||
Symptoms |
Air can be heard escaping from the small hole on the side of the regulator assembly, close to the adjustment knob. |
||
Cause |
A steady stream of air (slightly audible) from the small threaded breather hole is normal. However, the airflow from this port should be steady; it should not pulsate. When the air is first turned on, it may cycle for a few minutes, but should even out after a short period of time. |
||
Solution |
If the air is pulsating, do not plug or interfere with the small threaded breather hole. This is a non-repairable unit. If it becomes defective, it must be replaced (part #50-2367A) rather than attempting to repair it. |
||
See also |
Regulator Principle of Operation -- compares the old Festo regulators with the new SMC regulators |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
02 Oct 2001 |
||