Symptoms |
When the operator pulls the cassette out for loading, the lights on the chariot behave differently. The stop light and in arrow lights toggle and the sound of the chariot latch unlocking can be heard. The lights also flicker as they do at the end of the load cycle. This is a dangerous situation because the cassette can easily drop off the chariot and it may cause injury of damage. |
||
Cause |
Faulty cassette sensor switch inside the MCU.
|
||
Solution |
Use the command cass when the cassette is all the way out on the chariot. Under the heading Plate cassette sensors, check the status of the cassette being loaded. The status should be Offline and Not detected by sensors. If the status says Detected by sensors then there is a problem with the cassette switch inside the MCU, the wire, or the genine. The switch should be replaced. |
||