Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Lytron MCS50 series Heat Exchanger



Commands | Description | MSDS | NVS parameters | Parts | Planned Maintenance | Procedures | Troubleshooting

Description

On some output devices, heat exchangers are used as a replacement for the Polyscience chillers for cooling thermal 1.7x heads. They are far less complex and more reliable than chillers and use the same pre-mixed coolant that chillers use. A heat exchanger uses ambient temperature air to remove heat from the head's coolant fluid. It consists of a heat exchanger block, a pump, a coolant reservoir, and 3 fans to blow air through the heat exchanger block. Because the heat exchanger runs continuously, there is no need for a signal interface to the output device. The heat exchanger must not be installed near a heat source or warm air exhaust as this will affect its performance.
Heat exchangers are available in two models (includes heat exchanger, funnel, coolant, and brass fittings):

Note:

The interface in the Polyscience chiller has a jumper across pins 1 and 9 which is used as a cable detect signal by the Trendsetter. The heat exchanger does not require an interface cable to the Trendsetter, but the firmware still expects a cable detect jumper on the interface. A jumper plug (Creo part number 220-01149A) has been created to provide the cable detect signal by connecting pins 1 and 9. This plug connects to the Chiller connector on the debris removal cabinet or to the interface on the Trendsetter if there is no debris unit installed. If the jumper plug was not shipped with one of the early heat exchanger shipments, then order a jumper plug. As a temporary measure, connect a jumper between pins 1 and 9 on the connector or mask status #25 in the firmware (mask on 25, nvs save status 1).

Procedures

For information on operating and replacing the heat exchanger, refer to the manual supplied with the heat exchanger.

Planned Maintenance

Refer to the manual supplied with the heat exchanger for the most up-to-date procedures.

Operator maintenance (weekly)

Preventive maintenance (during PM)

MSDS

New! All MSDS information is now available through one portal. Go to http://msds.kpgraphics.com/company/index.asp for the most current MSDS.

Troubleshooting

Commands and NVS parameters

Because there is no electrical interface between the heat exchanger and output device, the commands and parameters used for the chiller will have no effect on the heat exchanger. Some useful commands for systems equipped with a heat exchanger are:

Parts

The air filter and the water filter are available directly from Lytron. The water filter is a standard 5-micron filter and can be ordered from a number of suppliers. Lytron part numbers are listed in the back of the Lytron operator manual.

Part description Lytron part number Creo part number
Heat exchanger kit, jumper   512-00298A
Air filter (12 x 14 x 0.5 in.) 330-0021 328-00026
5-micron water filter 330-0022 390-00259
Funnel with nozzle extension   390-00243
Pre-mixed coolant   82-1032A
Jumper plug   220-01149A
FTG,3/8 male NPT,1/2 Male NPT Straight   55-1312 qty:2
FTG,90Deg,forged,street,3/8”NPT,brass   55-0422 qty:2
FTG,Plug,Male,No-Drip disconnect,3/8”   55-0679 qty:2