Assemble the workstation following the manufacturer's instructions.
Check that the customer AC receptacle is wired correctly, and on the
same AC panel as the AC receptacle for the Trendsetter VLF.
Plug the UPS into the AC main and connect the workstation to the UPS.
Connect the workstation to the network and phone line..
Power up the workstation.
Log into Windows NT under the Administrator account.
Create a new directory called E:\Service. You will store Notepad
text files here to log service calls, firmware upgrades, workstation
upgrades and NVS backups.
Set the present time for the local time zone.
Dial the modem number from another phone, or use RAS from a laptop and
another line, to check that the phone connection and modem work.
Start the Diagnostic Interface serial communications program (e.g.,
Terminal).
Run the setup utility to set the correct baud rate, port, etc.
Power down the workstation.
Connect the serial cables from the workstation to the Computer Serial
Interface and Diagnostic sports on the Trendsetter VLF.
Connect the differential SCSI cable from the workstation to the VLF
Trendsetter.