Autoloader What to Do What to Look For Procedure

Parts

Single Cassette Unit      
  **Remove the side panels and power box cover.**
Genine 1 Visually inspect the lights on the board.    
PDB Visually inspect the lights on the board.    
Carriage driver board Visually inspect the lights on the board.    
Manifold Inspect the manifold assembly for leaks and overall condition.    
Cassette doors Check for smooth and symmetrical operation.    
Cassette to plenum height Check the distance with the verification tool at both ends of the plenum on all cassettes. Record the dimensions.    
  **Run a load sequence on all cassettes.**
Cassette/cart latch Check for smooth and positive engagement on all cassettes.    
Cassette/cart casters Check for wear and loose fasteners.    
Cassette cover Check for smooth operation, light tightness and overall condition.    
Media position Check that media is being centered. There should be a 1-2mm gap between the media edge and the side and rear guides. Check for slip sheets being pinched.  
Reflective tape Check that tape is intact in all cassettes. Replace as required.    
Slip Sheet Removal Unit      
Rollers Check for excessive wear and smooth operation.    
Roller preload Check the alignment of the two rollers.    
Roller shield Check the clearance between the rollers and shields.    
Roller actuators Check for leaks and loose fittings.    
Roller drive Check the alignment between the roller and the motor.    
Manifold Inspect the manifold assembly for leaks and overall condition.    
Compactor Check for smooth and quiet operation.    
Straight Conveyor      
Genine 4 Visually inspect the lights on the board.    
Belts Visually inspect the condition and tension of each belt.    
Speed Ensure that the conveyor matches the processor.    
L Conveyor      
Genine 4 Visually inspect the lights on the board.    
Carriage driver board Visually inspect the lights on the board.    
Manifold Inspect the manifold assembly for leaks and overall condition.    
X-axis Check for smooth operation.    
X-axis belt Visually inspect the condition and tension of each belt.    
Y-axis Check for smooth operation.    
Y-axis belt Visually inspect the condition and tension of each belt.    
Rotator Check rotation angle.    
Rotator vacuum      
Rotator vacuum generator filter Remove and inspect the filter. Replace as required.    
Lift Check for smooth and symmetrical operation.    
Speed Ensure that the conveyor matches the processor.    
  **Continue with the Workstation, Service Comments, and Customer Acceptance steps in the PM.**