Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Jobs fail in CS Xpose with “System fail in SCSI adapter driver” or “Job aborted by host” error message


Product

 
  • CS Xpose 2.00.x
  • Prinergy® 2.1
  • Lotem Controller 3.5.1 and 3.6
  • Lotem™ 800II / Lotem Quantum family

Platform

 

Dell® 2500H, 2500V and 6400 workstations

Operating system

 

Windows® 2000 Server


Error

 
  • Event Viewer: “System fail in SCSI adapter driver”
  • Lotem PC Controller: “Job aborted by host”

Symptoms

 

Sometimes, after three to five percent of a job separation has been exposed, the job fails in CS Xpose with one of the following error messages:

  • Event Viewer: “System fail in SCSI adapter driver”
  • Lotem PC Controller: “Job aborted by host”

Cause

  The maximum amount of time that CS Xpose waits for the Lotem to be ready for data is not long enough.

Solution

 
  1. On the Prinergy Workstation desktop, click the Start menu>Run, to open the Run dialog box.
  2. In the Open box, type RegEdit.
  3. Click OK.
  4. In the Registry Editor, browse to: HKEY_LOCAL_MACHINE\SOFTWARE\SCITEX\SEXStation\Engine\
  5. Double-click uSCSIPrintTimeOutSec.
  6. In the Edit DWord Value dialog box, select the Decimal option.
  7. In the Value box, type 180.
  8. Click OK.
  9. Close the RegEdit dialog box.

Technical contact(s)
 

David Weill

Submitted by
 

Tamari Kadman

Date submitted
 

31 Jan 2003