Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In CS Xpose, a Job sent from Prinergy fails and the error message “Media is missing” appears


Product

 
  • CS Xpose 1.01.028
  • CS Xpose 2.00.x
  • Prinergy® 2.1
  • Lotem® Controller 3.5.1, 3.6 and 3.7
  • Lotem 800II / Lotem Quantum family

Platform

 

Dell® 2500H, 2500V and 6400 workstations

Operating system

 

Windows® 2000 Server


Error

 

Media is missing


Symptoms

 

The job fails and the error message Media is missing appears.


Cause

  After restarting the Render station that is connected to the Lotem 800 Quantum, the CS Xpose/Prinergy software sends the first job from Prinergy.

Solution

 

Make sure to restart in the correct order:

  1. Restart the Lotem 800 Quantum.
  2. Restart the Render station (W2K).
  3. Restart the CS Xpose application.
  4. Restart the Prinergy software (including the CS Xpose JTP).

Technical contact(s)
 

Tamar Kadaman

Submitted by
 

Tamar Kadman

Date submitted
 

25 Jan 2004