Files in TIFF workflow fail in CS Xpose 2.00.064 with an error message


Product

 
  • CS Xpose 2.00.064 + any update
  • Prinergy® 2.1 and later
  • Prinergy Evo 1.1 and later
  • Lotem® 800 Quantum / Lotem 800 II / Lotem 400 Quantum

Platform

 

All platforms supported by relevant products

Operating system

 

Microsoft® Windows® 2000 Server


Error

 
  • The Vector type Screen Processor requested in the current ScreenSet (for page <FileName>.TIF) is unavailable. Change ScreenSet or imagesetter
  • Layout marker library error. Mismatch screen type. Error Number: 5534

Symptoms

 

In CS Xpose 2.00.064 + any update, files in a TIFF workflow fail in CS Xpose with 2 error messages.


Cause

 

The device logical name in config is more than 14 characters.


Solution

 
  1. Close CS Xpose software.
  2. Repeat the config process, defining a shorter logical device name (less than 14 characters).
  3. Start CS Xpose software.
  4. Repeat the TIFF workflow.

Technical contact(s)
 

Tamar Kadman

Submitted by
 

Tamar Kadman

Date submitted
 

01 Mar 2006