Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error “Expose task failed due to lack of response from the workstation” when exposing to Lotem 800 II/Lotem 800 Quantum


Product

 
  • Xpo software 3.00.79
  • CS Xpose software 2.00.064 + any update
  • Prinergy software 2.x and later
  • Lotem 800 II platesetter, controller version 3.80.12 and 3.80.16
  • Lotem 800 Quantum platesetter, controller version 3.80.12 and 3.80.16

Platform

 

All platforms supported by relevant products

Operating system

 

Microsoft Windows 2000 Server


Error

  Expose task failed due to lack of response from the workstation

Symptoms

 

In Xpo software 3.00.79, or in CS Xpose 2.00.064 + any update, Prinergy jobs fail before the expose begins and an error message appears in the Lotem controller.


Solution

 

Install the BaseExpose patch:

  1. Close the Xpo or CS Xpose software.
  2. Close the Lotem controller software.
  3. Unzip BaseExpose.zip, using the password kodak.
  4. In the Lotem controller workstation, copy the BaseExpose.dll file to: C\Lotem
  5. Start the Lotem controller software.
  6. Start the Xpo or CS Xpose.

Technical contact(s)
 

Tamar Kadman

Submitted by
 

Tamar Kadman

Date submitted
 

25 Apr 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.