Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


The first job from Xpo 3.00.79 for Magnus 800/400Q and Lotem Quantum fails when submitted after starting the platesetter


Product

 
  • Kodak® Xpo 3.00.79 software
  • Kodak Prinergy® software all versions
  • Kodak Prinergy Evo™ software all versions
  • Kodak Magnus™ 800 platesetter
  • Kodak Magnus 400 Quantum platesetter
  • Kodak Lotem® 800 Quantum family

Platform

  All platforms supported by relevant products

Operating system

  All operating systems supported by relevant products.
Note: If installing on Microsoft® Windows Server® 2003 operating system, you need to install the Xpo3.00.79 Windows Server 2003 update first.

Symptoms

  The first job that is submitted after you start the platesetter fails. The expose fails although the plate is loaded.

Cause

  When the platesetter is shutdown, the Prinergy/Prinergy Evo render station loses the SCSI recognition, therefore the connection with the platesetter is lost.

Solution

 

You need to install the Xpo 3.00.79 SCSI update.

Prerequisites:

  • Xpo 3.00.79 software
  • Xpo3.00.79 Windows Server 2003 update is required when installing on Windows Server 2003 operating system. See Downloads page.

To install the update:

  1. On the Xpo workstation, quit all software applications and restart the workstation.
  2. Download Xpo3.00.79_SCSI.zip.
  3. Extract the compressed file using the password kodak.
  4. Double-click the Xpo3.00.79Upd01.exe file.
  5. Follow the wizard instructions. The workstation will automatically restart when the installation is complete.
  6. Start the Xpo software.
  7. Start the Prinergy/Prinergy Evo software.

Technical contact(s)
 

Tamar Kadman

Submitted by
 

Tamar Kadman

Date submitted
 

22 Feb 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.