Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In Xpo, When you send a TIFF file to a Lotem 400 Quantum platesetter with a 2400 dpi head, the job fails


Product

 
  • Kodak® Xpo™ 3.1.55 software for Kodak Magnus™ 800, Magnus 300 Quantum and Lotem® Quantum™ platesetters
  • Xpo 3.1.55 update 1
  • Kodak Prinergy® software all versions
  • Kodak Prinergy Evo™ software all versions
  • Kodak Lotem 400 Quantum platesetter (with a 2400 dpi head)

Platform

  All platforms supported by relevant products

Operating system

  All relevant operating systems

Symptoms

  In Xpo, when you send a TIFF file for exposure on a Lotem 400 Quantum platesetter,the job fails with error message number 5532.

 

Error

 

 

Layout marker library error. The job's resolution does not match the resolution of the device. The job has failed.

 

Solution

 

 

Install the following update:

On the Lotem Controller station:

  1. Quit the Lotem Controller software.
  2. Download Xpo_Lotem400Q_FixResolution.zip.
  3. Extract the compressed file, using the password kodak.
  4. Double-click the Lotem400Quantum.ChangeMinRes.reg file.
  5. Start the Lotem Controller software.

On the Xpo (Prinergy/Prinergy Evo) station:

  1. Restart the Xpo software.

Technical contact(s)
 

Tamar Kadman

Submitted by
 

Tamar Kadman

Date submitted
 

23 Mar 2008


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.