Right-clicking on a collapsed job in the Pending Queue causes a Dr. Watson error
|
|---|
Applies to |
|
Problem |
After collapsing a job in the Pending Queue area of the main
Print Console screen (using the triangle icon), right-clicking on any white space in the
queue causes an exception error; the Print Console software crashes, and a Dr. Watson
error message is displayed. If the workstation is rebooted, the job files will be gone from the queue after restarting Print Console. The job files should be retained in the queue if you restart the Print Console software without rebooting the workstation. Note that this problem occurs regardless of the output device selection. |
Workaround |
Ensure that if and when you right-click on a collapsed job in the Pending Queue, you right-click directly on top of a job/file and not on any of the white space in the queue. |
Permanent Fix |
This problem has been fixed in Print Console version 1.0.3.2.
To upgrade to Print Console 1.0.3.2:
|
Technical contacts |
Jose Delgado, x2319 |
Date submitted |
February 25, 2000 |
Last modified |