Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Multiple Copy Option in Job Properties Not Working


Product

 

Print Console 1.0

Platform

 

Alpha, Intel

Operating system

 

Windows NT SP4


Error

 

Unable to Open File


Symptoms

 

When using the Copy option in the Job Properties dialog box to image multiple copies of the same file, Print Console images the first file correctly, but all subsequent files fail and are either deleted or moved to the Done folder from the Working folder (if the system is using Hot Folders and has the Done folder configured). When Print Console checks the Working folder to output the job again, the file is no longer there. Hence the “Unable to Open File” error message.


Cause

 

Caused by a limitation in the Print Console software.


Solution

 

No workaround exists for systems not using the Hot Folder input mechanism. Systems using the Hot Folder mechanism can image multiple copies of the same file using the following workaround:

1. Using the options in the Hot Folder pane, make sure a Done folder is set up in the Hot Folder.

2. Submit the file via the Hot Folder.

3. Using Windows NT Explorer, move the file from the Done folder to the Hot Folder.

4. Repeat as necessary.


Technical contact(s)
 

Jose Delgado

Sam Cirka

Submitted by
 

Jose Delgado

Date submitted
 

10 Oct 2001


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.