Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
|||
Product |
|
||
|
|
|||
Symptoms |
Stepping artifact found at edge of plates when processing an image that has sharp edges not parallel to edge of plate. |
||
|
|
|||
Cause |
Calculation error in Screen2Go when units are in metric |
||
|
|
|||
Solution |
Since the problem is caused by a miscalculation in Screen2Go when units are set to millimetres, use inches instead. |
||
|
|
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
04 Jun 2001 |
||