Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
|||
Product |
|
||
Platform |
Intel |
||
Operating system |
Windows NT SP4, Windows 2000 |
||
|
|
|||
Error |
No error message. |
||
|
|
|||
Symptoms |
Although Prinergy shows a file has been successfully generated, it never reaches the Print Console queue. The problem occurs only if the file is sent while Print Console is processing another image. You will not encounter this if you wait for each file to image before sending the next file. |
||
|
|
|||
Cause |
Although it doesn't appear so in Prinergy, Prinergy sends files with duplicate file names to Print Console. Since Print Console keeps the active file in the Working folder while the device outputs it, when the new file gets put in the same folder, the active file is overwritten. That file is then moved to the Done folder, or deleted if the Done folder is not set up. How do two different files end up with the same name when they are sent to Print Console? Prinergy uses the following file naming convention:
|
||
|
|
|||
Solution |
In Prinergy, either increase the maximum allowable length for job names or create job names that have unique initial characters. |
||
|
|
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
14 Sep 2001 |
||