Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Print Console, version 4.3 | ||
Machines affected |
|
||
Symptoms |
After installing Magnus VLF/Magnus VLF AL CR 3.0, you receive errors that indicate a problem with the configuration between the output device and the workflow. Some typical errors are 39430, 39433, and 39434. For example:
The Versioner configuration indicates that you have installed the correct version of Print Console. |
||
Cause |
The wrong version of Print Console was included on an early version of the CR 3.0 installation CD. The version on the CD is Print Console 4.3.0.224. It should be Print Console 4.3.0.232, but the Versioner is not detecting this error. |
||
Solution |
Confirm the version of Print Console on the Magnus VLF CR 3.0 installation CD. If it is not 4.3.0.232, order a new CR 3.0 CD. | ||
Technical contact(s) |
Al Edge | ||
Date submitted |
06 Nov 2006 | ||