Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Magnus VLF with CR 3.0 won't accept jobs from the workflow


Product

  Print Console, version 4.3

Machines affected

 
  • Magnus VLF
  • Magnus VLF AL

Symptoms

 

After installing Magnus VLF/Magnus VLF AL CR 3.0, you receive errors that indicate a problem with the configuration between the output device and the workflow. Some typical errors are 39430, 39433, and 39434. For example:

39433 GIM No group available

The Versioner configuration indicates that you have installed the correct version of Print Console.


Cause

 

The wrong version of Print Console was included on an early version of the CR 3.0 installation CD. The version on the CD is Print Console 4.3.0.224. It should be Print Console 4.3.0.232, but the Versioner is not detecting this error.


Solution

  Confirm the version of Print Console on the Magnus VLF CR 3.0 installation CD. If it is not 4.3.0.232, order a new CR 3.0 CD.

Technical contact(s)
  Al Edge
Date submitted
  06 Nov 2006

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.