Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
Kodak Magnus VLF GMCE platesetters with Print Console 4.x and Prinergy 3.1 |
||
Symptoms |
|
||
Cause |
This is caused by a change in the network binding order when the GMCE card is installed. If the GMCE card is first in the binding order, Orbacus binds to the GMCE card instead of the local area network. Print Console attempts to talk to the primary server through the GMCE card and fails to start. |
||
Solution |
Configure the network connections so that the Local Area Connection comes before the GMCE Connection. See page 6 of GMCE Intel Pro/1000 MT Server Adapter: Installation, Configuration and Testing for the procedure. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
6 June 2007 |
||