Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Print Console 4 | ||
Machines affected |
Trendsetter NEWS GMCE devices connected to preloaders |
||
Symptoms |
When an operator attempts to update Print Console 4 with the number of plates loaded, Print Console does not accept any value over 500. |
||
Cause |
If a Trendsetter NEWS device is set up to use a third-party preloader, the preloader can function as a large bay for the device (if the preloader option is enabled) or the Trendsetter device can pick plates from either its own bay or from the preloader (if the dual bay option is enabled). Depending on the option selected and the type of plates used, as many as 600 plates can be loaded into the system. Print Console, however, has been hard-coded with a maximum plate quantity of 500. |
||
Solution |
Use this procedure to change the maximum plate quantity value from 500 to 600:
|
||
Technical contact(s) |
Jose Delgado | ||
Date submitted |
11 Dec 2007 | ||