Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Particulate only collection (POC) debris removal is not enabled on this device (error #27002/43002)


Product

 
  • Platesetter 3244
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter Autoloader
  • Trendsetter NEWS
  • Trendsetter Spectrum
  • Trendsetter VLF
  • Trendsetter VLF Autoloader
  • VLF Platesetter

Machines affected

 

All machines with Firmware 0 or Firmware 1.


Component

 

UDRC (B-configuration), Firmware - POC Start


Error

 

27002/43003:  Particulate only collection (POC) debris removal is not enabled on this device


Symptoms

 

The firmware command POC start fails.


Cause

 

Debris removal is not configured in NVS.


Solution

 

If the media requires debris removal, and a UDRC has been installed and is connected to the output device:

  • For MPE devices, check that the NVS value SET SYS DBIN is set to 1 for POC debris removal.
  • For MCE devices, check that OPTION DEBRIS UDRCB ENABLE is enabled.
  • For Lotem Control Software, check that the following registry parameters are set:
    • ..\LOTEM400V\MACHINE\UDRC Installed
      (set to 1 for UDRC-B)
    • ..\LOTEM400V\IO OBJECTS\DISTRIBUTION\SOLENOIDS SWITCH\Debris Removal\Open
      (set to 1)


Technical contact(s)
 

Chi Tsang

Submitted by
 

Ryan Hines

Date submitted
 

30 Sep 2003