Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


The air jet is enabled, but not turned on (error #27004/43004)


Product

 
  • Platesetter 3244
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter Autoloader
  • Trendsetter NEWS
  • Trendsetter Spectrum
  • Trendsetter VLF
  • Trendsetter VLF Autoloader
  • VLF Platesetter

Machines affected

 

All machines with Firmware 0 or Firmware 1.


Component

 

UDRC, Firmware - Air jet monitor


Error

 

27004/43004:  The air jet is enabled, but not turned on


Symptoms

 

The air jet is not on during imaging with debris removal


Cause

 

The air jet has been turned off in diagnostics using the ACT DBLOW OFF command, bypassing the debris task.


Solution

 

Synchronize the debris task by turning on the air jet using the ACT DBLOW ON command. Resubmit the job or re-issue the PLOT command.


Technical contact(s)
 

Tony Lamprecht

Submitted by
 

Ryan Hines

Date submitted
 

30 Sep 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.