The blower is not turned on (error #27005/43005)


Product

 
  • Platesetter 3244
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter Autoloader
  • Trendsetter NEWS
  • Trendsetter Spectrum
  • Trendsetter VLF
  • Trendsetter VLF Autoloader
  • VLF Platesetter

Machines affected

 

All machines with Firmware 0 or Firmware 1.


Component

 

UDRC motor, Firmware - POC monitor, PACC monitor


Error

 

27005/43005:  The blower is not turned on


Symptoms

 

The UDRC is not running.


Cause

 

Blower has been turned off in diagnostics using the ACT command.


Solution

 

Synchronize the debris task by turning off the blower using the DEBRIS POC OFF or DEBRIS PACC OFF command, as applicable.


Technical contact(s)
 

Tony Lamprecht