Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
All machines with Firmware 0 or Firmware 1. |
||
Component |
UDRC Blower - POC monitor, PACC monitor |
||
Error |
27006/43006: The flow rate is below the minimum required |
||
Symptoms |
Blower performance is below the minimum necessary to collect debris. |
||
Cause |
The voltage is too low at the cabinet, or the filter has plugged suddenly, or there is mechanical damage to the blower. |
||
Solution |
Cause 1: Voltage too low at the cabinet. The cabinet has been moved to a lower voltage location or a long extension cord has been added.
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
30 Sep 2003 |
||