27007 (MPE) / 43007 (MCE / Lotem Control Software): Cabinet has lost power |
||
Symptoms |
Symptom #1: The green light on top of the cabinet comes on and then goes off without the blower coming on.
|
||
Causes/Solutions |
The green light indicates power (coming from the device cable) to the UDRC relay. Cause of Symptom #1: If the green light on top of the cabinet has turned on and then off again, the power supply to the cabinet may have failed.
WARNING: The UDRC runs off 200-240 VAC. Please use appropriate precautions when tracing main power problems. Cause of Symptom #2: If the green light on top of the cabinet never comes on, the bulb may be burnt out, the connections may be loose, the UDRC relay may be broken, or the cabinet may have overheated.
|
||
Technical contact(s) |
Tony Lamprecht (hardware)
|
||