Product |
|
- Platesetter 3244
- ThermoFlex
- Trendsetter 400/800
- Trendsetter Autoloader
- Trendsetter NEWS
- Trendsetter Spectrum
- Trendsetter VLF
- Trendsetter VLF Autoloader
- VLF Platesetter
|
|
Machines affected |
|
All machines with Firmware 0 or Firmware 1. |
|
Component |
|
UDRC, Particulate Filter. POC Monitor, PACC Monitor |
|
Error |
|
27010/43010: The particulate filter is full. You must replace the particulate filter to continue imaging. |
|
Symptoms |
|
Flow is below the minimum allowable. You may have recently seen the error number 27009/43009: particulate filter almost full. |
|
Cause |
|
The debris removal particulate filter is almost full, or the NVS/software parameters are incorrect, or a brand new particulate filter has been installed. |
|
Solution |
|
Cause 1: The particulate filter is full.
Solution: Replace the particulate filter and order a replacement. See the label on the back of the cabinet, the user guide, or the filter itself for the filter part number.
Note: Once the filter is full you cannot image plates until it is replaced.
Cause 2: Incorrect NVS/software parameters.
Solution: Type set debris or look up the UDRC registry values. Compare these values to the master reference tables on page 1 of the Debris Removal Firmware Guide - Parameter Values, Descriptions and Flowchart.
Cause 3: The error message displays right after a brand new particulate filter has been installed.
Solution:
- Clean the debris collection nozzle, especially the small pressure sensing hole in the nozzle.
- Check along the length of the vacuum collection hose for small holes, poor hose connections, or kinks.
- If this is a UDRC-L (with chemical filter), inspect the top of the chemical filter. There should be a white filter paper just below the filter screen. If there is a leak in the particulate filter (blown gasket or puncture), the filter paper will no longer be white (its new colour depends on the media type). To clean the chemical filter:
- Blow off the accumulation of debris on the chemical filter paper using compressed air
- Reinstall the chemical filter
- Check for an increase in the system flow rate.
- Check that the UDRC main power is plugged into a receptacle with sufficient voltage (200 VAC).
|
|
Technical contact(s) |
|
Tony Lamprecht |
Submitted by |
|
Ryan Hines |
Date submitted |
|
30 Sep 2003 |