Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


The debris hose is disconnected (error #27012/43012)


Product

 
  • Platesetter 3244
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter Autoloader
  • Trendsetter NEWS
  • Trendsetter Spectrum
  • Trendsetter VLF
  • Trendsetter VLF Autoloader
  • VLF Platesetter

Machines affected

 

All machines with Firmware 0 or Firmware 1.


Component

 

UDRC, Debris hose, vacuum line - PACC Monitor


Error

 

27012/43012:  The debris hose is disconnected


Symptoms

 

There is no flow at the nozzle, but there is flow at the UDRC.


Cause

 

The debris hose is disconnected or the nozzle sensor tube to the nozzle pressure sensor (in the output device) is not attached or has a hole/kink.


Solution

 

Cause 1:  The debris hose is disconnected.
Solution:

  1. Check all debris hose connections between the UDRC and the nozzle. Reattach if necessary.
  2. Check for large holes in the debris hose. Replace as necessary.
Cause 2:  The nozzle sensor tube to the nozzle pressure sensor (in the output device) is not attached or has a hole/kink.
Solution:  Reconnect or replace the sensor tube, making sure that it is connected to the "LOW" port on the Setra brand sensor.


Technical contact(s)
 

Tony Lamprecht

Submitted by
 

Ryan Hines

Date submitted
 

30 Sep 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.