Machines affected |
All machines with Firmware 0 or Firmware 1. |
||
Component |
UDRC (L configuration), Setra pressure sensor - PACC Monitor |
||
Error |
27013/43013: There is a problem with one or more of the pressure sensors in the debris removal cabinet |
||
Symptoms |
There is no flow at the nozzle, but there is flow at the UDRC. |
||
Cause |
The vacuum sensor tubes are connected incorrectly or not connected, or the sensors are not properly connected electrically, or the NVS parameters max_flow_change_rate_setra or flow_zero are set incorrectly. |
||
Solution |
Cause 1: The vacuum sensor tubes are connected incorrectly or not connected.
Solution: Unplug and reseat the electrical connections in the backpack on the LIONEL circuit board labeled AN1, AN2, and AN3. Ensure that AN1 goes to the 0-10" Setra pressure sensor and that AN2 goes to the 0-100" Setra pressure sensor. Cause 3: The NVS parameters max_flow_change_rate_setra or flow_zero are set incorrectly. Solution: Using the nvs command set debris or by checking the Lotem UDRC Registry:
|
||