Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


The chemical filter has expired. You must replace the chemical filter and reset the output device to continue imaging (error #27020/43020)


Product

 
  • Platesetter 3244
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter Autoloader
  • Trendsetter NEWS
  • Trendsetter Spectrum
  • Trendsetter VLF
  • Trendsetter VLF Autoloader
  • VLF Platesetter

Machines affected

 

All machines with Firmware 0 or Firmware 1.


Component

 

UDRC (L Configuration), Chemical Filter - PACC Start


Error

 

27020/43020:  The chemical filter has expired. You must replace the chemical filter and reset the output device to continue imaging.


Symptoms

 

 


Cause

 

The chemical filter is full.


Solution

 

Replace the filter and order a replacement. See the label on the back of the cabinet, the user guide, or the filter itself for the filter part number. You MUST perform a hard reset after replacing the filter (turn the output device off / on).

Note:  Once the filter is full, you can no longer image plates until it is replaced.


Technical contact(s)
 

Tony Lamprecht

Submitted by
 

Ryan Hines

Date submitted
 

30 Sep 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.